Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study
The Journal of Prosthetic Dentistry · 2024-04 · 131 (4) · 618-625
DOI: 10.1016/j.prosdent.2022.07.004 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2024-04. Verfasst von Najla Chebib und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research and Teaching Fellow, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Ge…. Hauptthemen laut MEDLINE: Computer-Aided Design, Mouth, Edentulous. Die Arbeit wurde bisher 58-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
STATEMENT OF PROBLEM: Although the intraoral scanning of edentulous ridges is feasible, clinical evidence that the resulting denture retention is equivalent to that achieved with conventional impressions is lacking. PURPOSE: The purpose of this clinical study was to determine the retention of complete denture bases fabricated from digital intraoral scans versus conventional impressions by using border molding and posterior palatal seal compression. MATERIAL AND METHODS: Twenty volunteers with an edentulous maxilla were recruited. An intraoral scan of the maxilla and a conventionally border-molded impression with a custom tray were made. The conventional impression was poured; the definitive cast was scanned. Three-dimensionally (3D) printed (PB1) and milled bases (MB1) were fabricated based on the scan of the definitive cast. Based on the intraoral scan, a 3D printed (PB2) and a milled base (MB2) were fabricated. On each base, a platform with a hook consisting of a central notch orienting the force against the post dam (PD) and 2 lateral notches orienting the forces against the left (LT) and right (RT) tuberosities was set in the center of the outer surface of the base. A traction dynamometer was inserted in the hook and oriented into the corresponding notch by applying force until dislodgement. All bases were subsequently stored in artificial saliva for 2 weeks and scanned. Retention testing was repeated by using the same procedure. To evaluate trueness and to visualize the differences on a color map, the scan of the definitive cast and the intraoral scans were matched and compared in 3 dimensions. The Wilcoxon tests were used to compare the retention of the different bases (95% confidence interval, α=.05). RESULTS: Nineteen participants with a mean ±standard deviation age of 64.1 ±14.7 years completed the 4 study sessions. The retention of printed bases (PD: 16.08 ±15.28 N; LT: 14.98 ±14.72 N; RT: 11.28 ±9.57 N) and milled bases (PD:14.52 ±17.07 N; RT: 11.99 ±12.10 N; LT: 13.55 ±15.53 N) fabricated from conventional impressions presented significantly higher retentive forces than those printed (PD: 6.21 ±4.72 N; RT:5.12 ±2.78 N; LT: 4.45 ±2.77 N) and milled (PD: 6.58 ±4.92 N; RT: 4.65 ±2.63 N; LT: 5.02 ±3.58 N) from the intraoral scans (P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research and Teaching Fellow, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland. Electronic address: Najla.Chebib@unige.ch.
- Research and Teaching Fellow, Division of Fixed Prosthodontics, School of Dentistry, Meikai University, Saitama, Japan; Research and Teaching Fellow, Department of Geriatric Dentistry, School of Dentistry, Showa Univers…
- Professor, Department of Prosthodontics and Cranio-Facial Research Laboratory, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon; Lecturer, Center for Research in Clinical Odontology, Univer…
- Professor, Clinic of General-, Special care and Geriatric Dentistry, Center of Dental Medicine, University of Zurich, Zurich, Switzerland; Research and Teaching Fellow, Division of Gerodontology and Removable Prosthodon…
- Professor, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland; Professor, Division of Geriatrics, Department of Rehabilitation and Ge…
- Research and Teaching Fellow, Division of Gerodontology and Removable Prosthodontics, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland.
Zitieren
APA
Chebib, N., Imamura, Y., El Osta, N., Srinivasan, M., Müller, F., & Maniewicz, S. (2024). Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study. The Journal of Prosthetic Dentistry, 131(4), 618-625. https://doi.org/10.1016/j.prosdent.2022.07.004
Vancouver
Chebib N, Imamura Y, El Osta N, Srinivasan M, Müller F, Maniewicz S. Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study. The Journal of Prosthetic Dentistry. 2024;131(4):618-625. doi:10.1016/j.prosdent.2022.07.004
BibTeX
@article{Chebib2024,
author = {Chebib, Najla and Imamura, Yoshiki and El Osta, Nada and Srinivasan, Murali and Müller, Frauke and Maniewicz, Sabrina},
title = {Fit and retention of complete denture bases: Part II – conventional impressions versus digital scans: A clinical controlled crossover study},
journal = {The Journal of Prosthetic Dentistry},
year = {2024},
volume = {131},
number = {4},
pages = {618--625},
doi = {10.1016/j.prosdent.2022.07.004}
}
EUVIMED