EUVIMEDEUVIMED entdecken
Studienprotokoll

Impact of imaging protocol and tube current adjustment on the radiation dose in CBCT imaging of mandibular incisors

Jardel Francisco Mazzi-Chaves, Iago Ramirez, Grasielle Camargo Gonçalves Alcebíades, Julia Godoi Lopes, Amanda Pelegrin Candemil, Rocharles Cavalcante Fontenele, Fabiane Carneiro Lopes-Olhê, Cassiana Viccari, Patricia Nicolucci, Danieli Moura Brasil, Christiano Oliveira-Santos, Manoel Damião Sousa-Neto und 1 weitere

Clinical Oral Investigations · 13.08.2025 · 29 (9)

DOI: 10.1007/s00784-025-06499-8 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Clinical Oral Investigations, online erschienen am 13.08.2025. Verfasst von Jardel Francisco Mazzi-Chaves und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Restorative Dentistry, The School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café - Subsetor Oeste - 11 (N-11), Ri…. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Incisor, Radiation Dosage, Mandible. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: This study aimed to assess the impact of imaging protocols involving tube current (mA) adjustment on the equivalent and effective radiation dose for cone-beam computed tomography (CBCT) of mandibular incisors using the corresponding periapical radiography as clinical reference. METHODS: An anthropomorphic head and neck phantom equipped with 24 thermoluminescent dosimeters (TLDs) was used to evaluate radiation exposure across seven imaging protocols: high-dose CBCT (4.0, 7.1, and 10 mA), low-dose CBCT (3.2, 4.5, and 6.3 mA), and standard periapical radiography (7 mA). Equivalent and effective radiation doses were calculated according to tissue-weighting factors outlined in ICRP Publication 103. RESULTS: Effective dose increased proportionally with tube current, ranging from 53 to 175 µSv in high-dose protocols and from 8.6 to 18 µSv in low-dose protocols. Periapical radiography yielded the lowest effective dose (1.4 µSv). The highest equivalent doses were recorded for the salivary glands and oral mucosa across all protocols. CONCLUSIONS: CBCT protocols with reduced tube current significantly decrease radiation exposure. The lowest setting tested (3.2 mA) resulted in an effective dose comparable to six periapical radiographs. These findings support the implementation of low-dose CBCT for complex endodontic diagnostics, particularly during initial evaluations, in alignment with the ALADAIP principle.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cone-Beam Computed TomographyIncisorRadiation DosageMandibleHumansPhantoms, ImagingThermoluminescent Dosimetry

Stichwörter der Autor:innen

Cone-beam computed tomographyDose optimizationDosimetryMandibular incisorsRadiation doseRadiological protection

Autor:innen und Institutionen

  • Department of Restorative Dentistry, The School of Dentistry of Ribeirão Preto, University of São Paulo, Av. do Café - Subsetor Oeste - 11 (N-11), Ribeirão Preto, São Paulo, Ribeirão Preto, 14040-904, SP, Brazil. jardel…
  • Department of Restorative Dentistry, The School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Department of Stomatology, Public Health, and Forensic Dentistry, The School of Dentistry of Ribeirão Preto, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.
  • Center for Instrumentation, Dosimetry and Radiation Protection (CIDRA), Department of Physics, Faculty of Philosophy, Sciences and Letters of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil.
  • Department of Diagnosis & Oral Health, University of Louisville School of Dentistry, Louisville, KY, United States of America.

Förderung

  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Zitieren

APA

Mazzi-Chaves, J. F., Ramirez, I., Alcebíades, G. C. G., Lopes, J. G., Candemil, A. P., Fontenele, R. C., Lopes-Olhê, F. C., Viccari, C., Nicolucci, P., Brasil, D. M., Oliveira-Santos, C., Sousa-Neto, M. D., & Gaêta-Araujo, H. (2025). Impact of imaging protocol and tube current adjustment on the radiation dose in CBCT imaging of mandibular incisors. Clinical Oral Investigations, 29(9). https://doi.org/10.1007/s00784-025-06499-8

Vancouver

Mazzi-Chaves JF, Ramirez I, Alcebíades GCG, Lopes JG, Candemil AP, Fontenele RC, et al. Impact of imaging protocol and tube current adjustment on the radiation dose in CBCT imaging of mandibular incisors. Clinical Oral Investigations. 2025;29(9). doi:10.1007/s00784-025-06499-8

BibTeX
@article{MazziChaves2025,
  author = {Mazzi-Chaves, Jardel Francisco and Ramirez, Iago and Alcebíades, Grasielle Camargo Gonçalves and Lopes, Julia Godoi and Candemil, Amanda Pelegrin and Fontenele, Rocharles Cavalcante and Lopes-Olhê, Fabiane Carneiro and Viccari, Cassiana and Nicolucci, Patricia and Brasil, Danieli Moura and Oliveira-Santos, Christiano and Sousa-Neto, Manoel Damião and Gaêta-Araujo, Hugo},
  title = {Impact of imaging protocol and tube current adjustment on the radiation dose in CBCT imaging of mandibular incisors},
  journal = {Clinical Oral Investigations},
  year = {2025},
  volume = {29},
  number = {9},
  doi = {10.1007/s00784-025-06499-8}
}
Kostenlos starten →