Efficacy of gonadal shielding in dose reduction for female pelvic radiography

Saki Nozoe, Kei Terazaki, Makoto Sasaki, Manabu Nakata

Radiation Protection Dosimetry · 2024

DOI: 10.1093/rpd/ncae116 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Saki Nozoe und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan. Hauptthemen laut MEDLINE: Radiation Protection, Radiation Dosage, Phantoms, Imaging, Ovary. Die Arbeit nennt 14 Literaturangaben. Gefördert von: Japan Society, Promotion of Science (JSPS) KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to evaluate the dose reduction using gonad shielding (GS) during pelvic imaging. Three types of pelvic images (radiography, magnetic resonance and computed tomography) were fused to elucidate the three-dimensional relationship between the position of ovaries and GS. To estimate the dose received by the ovaries, the off-axis dose at any given depth was measured under two different imaging conditions using thermoluminescence dosemeters and a polymethyl methacrylate phantom. The mean ovarian depth was 8.4 cm. The mean estimated ovarian dose without an additional filter was 0.36 mGy without GS and 0.14 mGy with GS. The mean estimated ovarian dose with an additional filter was 0.24 mGy without GS and 0.10 mGy with GS. The efficacy of ovarian dose reduction should be evaluated based on the achieved ovarian dose, considering the ovarian depth and use of additional filtration, rather than the ovarian protection rate of GS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionRadiation DosagePhantoms, ImagingOvaryPelvisFemaleHumansMagnetic Resonance ImagingTomography, X-Ray ComputedThermoluminescent DosimetryGonads

Autor:innen und Institutionen

  • Division of Clinical Radiology Service, Kyoto University Hospital, Kyoto, Japan.

Förderung

  • Japan Society
  • Promotion of Science (JSPS) KAKENHI

Zitieren

APA

Nozoe, S., Terazaki, K., Sasaki, M., & Nakata, M. (2024). Efficacy of gonadal shielding in dose reduction for female pelvic radiography. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae116

Vancouver

Nozoe S, Terazaki K, Sasaki M, Nakata M. Efficacy of gonadal shielding in dose reduction for female pelvic radiography. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae116

BibTeX
@article{Nozoe2024,
  author = {Nozoe, Saki and Terazaki, Kei and Sasaki, Makoto and Nakata, Manabu},
  title = {Efficacy of gonadal shielding in dose reduction for female pelvic radiography},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae116}
}
Kostenlos starten →