EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite

Florian Dold, Karolina Mueller, Martin Butz, Sebastian Hahnel

Clinical Oral Investigations · 12.03.2025 · 29 (4)

DOI: 10.1007/s00784-025-06259-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, online erschienen am 12.03.2025. Verfasst von Florian Dold und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthetic Dentistry, University Hospital Regensburg, Regensburg, Germany. Hauptthemen laut MEDLINE: Computer-Aided Design, Composite Resins, Dental Restoration, Temporary, Denture, Partial, Fixed. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Regensburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To determine the clinical performance of long-term temporary fixed dental prostheses (LTFDPs) manufactured from CAD/CAM temporary resin-based composite. Materials and methods Retrospective data of 46 patients supplied with 73 LTFDPs (partial coverage crowns, crowns, fixed dental prostheses) manufactured from a CAD/CAM resin-based composite luted either temporarily, selfadhsesively, or adhesively were analyzed for failures and complications.

Results

Datasets of 44 patients with 71 LTFDPs (12 partial-coverage crowns, 31 crowns, 28 fixed dental prostheses) were included in the analyses; median observation time was 362.0 days. Failures due to fracture occurred in 14.1% and decementation was observed in 18.1% of all LTFDPs. There was no statistically significant difference in failure rates between partial coverage crowns, crowns, and fixed dental prostheses. The probability of decementations was significantly higher in restorations that had been luted temporarily or selfadhesively than in those that had been luted adhesively.

Conclusions

LTFDPs fabricated from resin-based temporary composite with low filler content feature relevant failure rates, which is independent on the type of restoration. Decementation is a frequently observed complication and dependent on the mode of luting. Clinical Relevance LTFDPs fabricated from resin-based composite have similar failure rates as reported for polymethyl methacrylate based LTFPDs. Adhesive luting might help to reduce the probability of decementation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computer-Aided DesignComposite ResinsDental Restoration, TemporaryDenture, Partial, FixedDental Prosthesis DesignHumansRetrospective StudiesDental Restoration FailureMaleFemaleCrownsMiddle AgedAgedAdult

Stichwörter der Autor:innen

CompositeCrownFixed dental prosthesesFixed interim restoration

Substanzen

Composite Resins

Autor:innen und Institutionen

  • Department of Prosthetic Dentistry, University Hospital Regensburg, Regensburg, Germany.
  • Center for Clinical Studies, University Hospital Regensburg, Regensburg, Germany.
  • Private Dental Practice, München, Germany.
  • Department of Prosthetic Dentistry, University Hospital Regensburg, Regensburg, Germany. sebastian.hahnel@ukr.de.

Förderung

  • Universitätsklinikum Regensburg

Zitieren

APA

Dold, F., Mueller, K., Butz, M., & Hahnel, S. (2025). Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite. Clinical Oral Investigations, 29(4). https://doi.org/10.1007/s00784-025-06259-8

Vancouver

Dold F, Mueller K, Butz M, Hahnel S. Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite. Clinical Oral Investigations. 2025;29(4). doi:10.1007/s00784-025-06259-8

BibTeX
@article{Dold2025,
  author = {Dold, Florian and Mueller, Karolina and Butz, Martin and Hahnel, Sebastian},
  title = {Clinical performance of long-term temporary fixed dental prostheses fabricated from CAD/CAM resin-based composite},
  journal = {Clinical Oral Investigations},
  year = {2025},
  volume = {29},
  number = {4},