3D digital data analysis to identify factors influencing debonding of CAD-CAM resin composite molar crowns: A 4-year clinical study
Journal of Prosthodontic Research · 2026 · 70 (4) · 643-651
DOI: 10.2186/jpr.jpr_d_25_00149 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Prosthodontic Research, 2026. Verfasst von Shintaro Ban und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan. Hauptthemen laut MEDLINE: Computer-Aided Design, Molar, Crowns, Composite Resins. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 28 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: This study retrospectively investigated the clinical outcomes of computer-aided design/computer-aided manufacturing (CAD-CAM) resin composite crowns for molars and analyzed the morphological factors contributing to crown failure using three-dimensional (3D) digital data. METHODS: The clinical outcomes of 117 crowns in 101 patients treated at Osaka University Dental Hospital were analyzed. 3D digital data were evaluated to identify factors influencing crown debonding, focusing on luting methods, abutment morphology, and crown parameters. Survival analyses, multivariate analyses, and regression modeling were performed. RESULTS: During an observation period of up to 1281 days, the cumulative success and survival rates were 83.3% and 95.5%, respectively. Debonding (12.0%) was the most frequent complication and was significantly associated with the choice of luting materials (P < 0.001). In addition, 3D analysis identified greater buccolingual taper, insufficient occlusal thickness, smaller abutment surface area, and reduced abutment height as predictors of debonding. Nonlinear regression analysis revealed significant differences in the abutment parameters between SA Luting and PANAVIA V5 at the lower percentiles (P = 0.02). CONCLUSIONS: Combining clinical outcomes with 3D data highlights the importance of precise abutment preparation and material selection to reduce the risk of crown debonding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Fixed Prosthodontics, Osaka University Graduate School of Dentistry, Osaka, Japan.
- Department of Dental Biomaterials, Osaka University Graduate School of Dentistry, Osaka, Japan.
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Takamatsu, Japan.
- KU Leuven (University of Leuven), Department of Oral Health Sciences, BIOMAT & UZ Leuven (University Hospitals Leuven), Leuven, Belgium.
- Department of Medical Statistics, Osaka Metropolitan University Graduate School of Medicine and Faculty of Medicine, Osaka, Japan.
Zitieren
APA
Ban, S., Mine, A., Yamaguchi, S., Aoki-Matsumoto, M., Takaishi, M., Yumitate, M., Ishida, M., Van Meerbeek, B., Yatani, H., Ishigaki, S., Imazato, S., & Shintani, A. (2026). 3D digital data analysis to identify factors influencing debonding of CAD-CAM resin composite molar crowns: A 4-year clinical study. Journal of Prosthodontic Research, 70(4), 643-651. https://doi.org/10.2186/jpr.jpr_d_25_00149
Vancouver
Ban S, Mine A, Yamaguchi S, Aoki-Matsumoto M, Takaishi M, Yumitate M, et al. 3D digital data analysis to identify factors influencing debonding of CAD-CAM resin composite molar crowns: A 4-year clinical study. Journal of Prosthodontic Research. 2026;70(4):643-651. doi:10.2186/jpr.jpr_d_25_00149
BibTeX
@article{Ban2026,
author = {Ban, Shintaro and Mine, Atsushi and Yamaguchi, Satoshi and Aoki-Matsumoto, Mariko and Takaishi, Munechika and Yumitate, Masahiro and Ishida, Masaya and Van Meerbeek, Bart and Yatani, Hirofumi and Ishigaki, Shoichi and Imazato, Satoshi and Shintani, Ayumi},
title = {3D digital data analysis to identify factors influencing debonding of CAD-CAM resin composite molar crowns: A 4-year clinical study},
journal = {Journal of Prosthodontic Research},
year = {2026},
volume = {70},
number = {4},
pages = {643--651},
doi = {10.2186/jpr.jpr_d_25_00149}
}
EUVIMED