Accuracy of digital jaw relation determination in different occlusal conditions — an in vitro study
Clinical Oral Investigations · 2024
DOI: 10.1007/s00784-024-06101-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Oral Investigations, 2024. Verfasst von Daniel Hellmann und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, University of Würzburg, Pleicherwall 2, 97070, Würzburg, Germany. daniel.hellmann@uni-wuerzburg.de. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Models, Dental. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVES: In orthodontics, accurate registration of jaw relationships is essential for correct diagnosis and treatment planning. Therefore, accuracy of the digital spatial registration of maxillary and mandibular models and - for the first time-the influence of dentition stage and malocclusion type on this procedure were investigated under controlled conditions. MATERIALS AND METHODS: Eight pairs of jaw models, representing different occlusal and developmental statuses (m1-m8), were scanned using two IOS types (PS: Primescan; TR: Trios4). Buccal scans for registering maxillary and mandibular models were repeated (n = 3). Reference scans were obtained using a desktop scanner (RDS; Ceramill Map 600). Arch-specific 3D coordinate systems were used to calculate the linear and angular deviations among different registrations. Trueness of registration by PS and TR was calculated using a statistical mixed-effect model (random-effect: model-type). Precision values of IOS registrations across m1-m8 were characterized as standard deviations (SDs). RESULTS: As maximum deviations compared to RDS, PS showed caudal translation (0.11 ± 0.02 mm), while TR showed ventral translation (0.08 ± 0.06 mm), of the maxillary relative to the mandibular model. Maximum rotational values were calculated for tilting around the transverse axis (PS: anteinclination (0.25 ± 0.16°), TR: retroinclination (0.27 ± 0.16°)). These deviations varied with the malocclusion type. The lowest IOS precision was recorded for sagittal translation (PS: 0.013 ± 0.005 mm, TR: 0.021 ± 0.010 mm) and rotation around the transverse axis (PS: 0.051 ± 0.013°, TR: 0.076 ± 0.031°). CONCLUSIONS AND CLINICAL RELEVANCE: Registrations using buccal IOS scans showed quantifiable but clinically negligible 3D deviations from reference scan registrations, whereby the type of tooth and jaw misalignment did not appear to have a clinically relevant influence. Therefore, the examined IOSs appear to be suitable for digital jaw relation determination in everyday clinical orthodontic practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics, University of Würzburg, Pleicherwall 2, 97070, Würzburg, Germany. daniel.hellmann@uni-wuerzburg.de.
- Dental Academy for Continuing Professional Development, Karlsruhe, Germany. daniel.hellmann@uni-wuerzburg.de.
- Department of Orthodontics, Ulm University, Ulm, Germany.
- Institute of Epidemiology and Medical Biometry, Ulm University, Ulm, Germany.
Zitieren
APA
Hellmann, D., Knoch, F. M., Repky, S., Kilic, F., Lapatki, B. G., & Radeke, J. (2024). Accuracy of digital jaw relation determination in different occlusal conditions — an in vitro study. Clinical Oral Investigations. https://doi.org/10.1007/s00784-024-06101-7
Vancouver
Hellmann D, Knoch FM, Repky S, Kilic F, Lapatki BG, Radeke J. Accuracy of digital jaw relation determination in different occlusal conditions — an in vitro study. Clinical Oral Investigations. 2024. doi:10.1007/s00784-024-06101-7
BibTeX
@article{Hellmann2024,
author = {Hellmann, Daniel and Knoch, Felix M and Repky, Stefan and Kilic, Fatih and Lapatki, Bernd G and Radeke, Johanna},
title = {Accuracy of digital jaw relation determination in different occlusal conditions — an in vitro study},
journal = {Clinical Oral Investigations},
year = {2024},
doi = {10.1007/s00784-024-06101-7}
}
EUVIMED