EUVIMEDEUVIMED entdecken
Crossref

Accuracy of maximum intercuspal position located by using four intraoral scanners and an artificial intelligence-based program

Marta Revilla-León, Lucía Fernández-Estevan, Abdul B Barmak, John C Kois, Jorge Alonso Pérez-Barquero

The Journal of Prosthetic Dentistry · 2025

DOI: 10.1016/j.prosdent.2024.03.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Prosthetic Dentistry, 2025. Verfasst von Marta Revilla-León und 4 weiteren Autor:innen. Beteiligte Einrichtung: Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, …. Hauptthemen laut MEDLINE: Artificial Intelligence, Dental Occlusion. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

STATEMENT OF PROBLEM: Maxillary and mandibular scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the accuracy of the AI-based program locating the MIP relationship is unknown. PURPOSE: The purpose of the present clinical study was to assess the accuracy of the MIP relationship located by using 4 intraoral scanners (IOSs) and an AI-based program. MATERIAL AND METHODS: Conventional casts of a participant mounted on an articulator in MIP were digitized (T710). Four groups were created based on the IOS used to record a maxillary and mandibular scan of the participant: TRIOS 4, iTero, i700, and PrimeScan. Each pair of nonarticulated scans were duplicated 20 times. Three subgroups were created: IOS, AI-articulated, and AI-IOS-corrected subgroups (n=10). In the IOS-subgroup, 10 duplicated scans were articulated in MIP by using a bilateral occlusal record. In the AI-articulated subgroup, the remaining 10 duplicated scans were articulated in MIP by using an AI-based program (BiteFinder). In the AI-IOS-corrected subgroup, the same AI-based program was used to correct the occlusal collisions of the articulated specimens obtained in the IOS-subgroup. A reverse engineering program (Geomagic Wrap) was used to calculate 36 interlandmark measurements on the digitized articulated casts (control) and each articulated specimen. Two-way ANOVA and pairwise multiple comparison Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison Wilcoxon rank tests were used to analyze precision (α=.05). RESULTS: Significant trueness discrepancies among the groups (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceDental OcclusionHumansJaw Relation RecordMandibleMaxillaModels, DentalImage Processing, Computer-Assisted

Autor:innen und Institutionen

  • Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Faculty and Director, Research and Digital Dentistry, Kois Cente…
  • Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.
  • Associate Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY.
  • Founder and Director, Kois Center, Seattle, Wash.; Affiliate Professor, Graduate in Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; and Private practic…
  • Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain.

Zitieren

APA

Revilla-León, M., Fernández-Estevan, L., Barmak, A. B., Kois, J. C., & Alonso Pérez-Barquero, J. (2025). Accuracy of maximum intercuspal position located by using four intraoral scanners and an artificial intelligence-based program. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2024.03.007

Vancouver

Revilla-León M, Fernández-Estevan L, Barmak AB, Kois JC, Alonso Pérez-Barquero J. Accuracy of maximum intercuspal position located by using four intraoral scanners and an artificial intelligence-based program. The Journal of Prosthetic Dentistry. 2025. doi:10.1016/j.prosdent.2024.03.007

BibTeX
@article{RevillaLen2025,
  author = {Revilla-León, Marta and Fernández-Estevan, Lucía and Barmak, Abdul B and Kois, John C and Alonso Pérez-Barquero, Jorge},
  title = {Accuracy of maximum intercuspal position located by using four intraoral scanners and an artificial intelligence-based program},
  journal = {The Journal of Prosthetic Dentistry},
  year = {2025},
  doi = {10.1016/j.prosdent.2024.03.007}
}
Kostenlos starten →