EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery

Yoana Malenova, Florian Ortner, Paris Liokatis, Selgai Haidari, Matthias Tröltzsch, Florian Fegg, Katharina T Obermeier, Jens T Hartung, Tamara K Kakoschke, Egon Burian, Sven Otto, Hisham Sabbagh und 1 weitere

Clinical Oral Investigations · 2023

DOI: 10.1007/s00784-023-05125-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Oral Investigations, 2023. Verfasst von Yoana Malenova und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, University Hospital LMU Munich, Munich, Germany. yoanamalenova@gmail.com. Hauptthemen laut MEDLINE: Orthognathic Surgery, Orthognathic Surgical Procedures, Surgery, Computer-Assisted, Dental Implants. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinik München.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. Material and Methods A retrospective analysis of 28 patients that underwent virtually planned orthognathic surgery with maxillary Le Fort I osteotomy either using VSP-generated splints ( n = 13) or patient-specific implants (PSI) ( n = 15) was conducted. The accuracy and surgical outcome of both techniques were compared by superimposing preoperative surgical planning with postoperative CT scans and measurement of translational and rotational deviation for each patient.

Results

The 3D global geometric deviation between the planned position and the postoperative outcome was 0.60 mm (95%-CI 0.46–0.74, range 0.32–1.11 mm) for patients with PSI and 0.86 mm (95%-CI 0.44–1.28, range 0.09–2.60 mm) for patients with surgical splints. Postoperative differences for absolute and signed single linear deviations between planned and postoperative position were a little higher regarding the x-axis and pitch but lower regarding the y- and z-axis as well as yaw and roll for PSI compared to surgical splints. There were no significant differences regarding global geometric deviation, absolute and signed linear deviations in the x-, y-, and z-axis, and rotations (yaw, pitch, and roll) between both groups.

Conclusions

Regarding accuracy for positioning of maxillary segments after Le Fort I osteotomy in orthognathic surgery patient-specific implants and surgical splints provide equivalent high accuracy. Clinical relevance Patient-specific implants for maxillary positioning and fixation facilitate the concept of splintless orthognathic surgery and can be reliably used in clinical routines.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthognathic SurgeryOrthognathic Surgical ProceduresSurgery, Computer-AssistedDental ImplantsHumansOcclusal SplintsRetrospective StudiesMaxillaComputersImaging, Three-DimensionalOsteotomy, Le Fort

Stichwörter der Autor:innen

CAD/CAMOcclusal splintOrthognathic SurgeryPSIPatient-specific implants

Substanzen

Dental Implants

Autor:innen und Institutionen

  • Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, University Hospital LMU Munich, Munich, Germany. yoanamalenova@gmail.com.
  • Department of Oral and Maxillofacial Surgery and Facial Plastic Surgery, University Hospital LMU Munich, Munich, Germany.
  • Center for Oral, Maxillofacial, and Facial Reconstructive Surgery, Ansbach, Germany.
  • Institute of Diagnostic and Interventional Radiology, Technical University of Munich, School of Medicine, Munich, Germany.
  • Department of Orthodontics and Dentofacial Orthopedics, University Hospital LMU Munich, Munich, Germany.

Förderung

  • Universitätsklinik München

Zitieren

APA

Malenova, Y., Ortner, F., Liokatis, P., Haidari, S., Tröltzsch, M., Fegg, F., Obermeier, K. T., Hartung, J. T., Kakoschke, T. K., Burian, E., Otto, S., Sabbagh, H., & Probst, F. A. (2023). Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. Clinical Oral Investigations. https://doi.org/10.1007/s00784-023-05125-9

Vancouver

Malenova Y, Ortner F, Liokatis P, Haidari S, Tröltzsch M, Fegg F, et al. Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery. Clinical Oral Investigations. 2023. doi:10.1007/s00784-023-05125-9

BibTeX
@article{Malenova2023,
  author = {Malenova, Yoana and Ortner, Florian and Liokatis, Paris and Haidari, Selgai and Tröltzsch, Matthias and Fegg, Florian and Obermeier, Katharina T and Hartung, Jens T and Kakoschke, Tamara K and Burian, Egon and Otto, Sven and Sabbagh, Hisham and Probst, Florian A},
  title = {Accuracy of maxillary positioning using computer-designed and manufactured occlusal splints or patient-specific implants in orthognathic surgery},
  journal = {Clinical Oral Investigations},
  year = {2023},
  doi = {10.1007/s00784-023-05125-9}
}
Kostenlos starten →