Novel CAD/CAM-splint-based navigation protocol enhances intraoperative maxillary position control in orthognathic surgery: a case control study
Head & Face Medicine · 10.01.2025 · 21 (1)
DOI: 10.1186/s13005-024-00477-3 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Head & Face Medicine, online erschienen am 10.01.2025. Verfasst von Felix Schrader und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany. Hauptthemen laut MEDLINE: Orthognathic Surgical Procedures, Maxilla, Surgery, Computer-Assisted, Computer-Aided Design. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts.
Abstract (Originalsprache)
Background
Virtual surgical planning for orthognathic surgery typically relies on two methods for intraoperative plan transfer: CAD/CAM occlusal splints and patient-specific implants (PSI). While CAD/CAM splints may offer limited accuracy, particularly in the vertical dimension, PSIs are constrained by higher costs and extended preparation times. Surgical navigation has emerged as a potential alternative, but existing protocols often involve invasive registration or lack transparent evaluation. This study introduces a novel protocol for point-based optical navigation using modified CAD/CAM splints for non-invasive registration and transparent intraoperative evaluation, assessing its effectiveness in maxillary positioning.
Methods
This prospective case-control study included 20 patients undergoing bimaxillary orthognathic surgery. The experimental group employed surgical navigation with modified CAD/CAM splints, while the control group used standard CAD/CAM splints. Surgical accuracy was evaluated by measuring translational and rotational discrepancies between the planned and achieved maxillary positions. A mixed ANOVA was conducted to assess other factors, aside from surgical navigation, that might influence surgical accuracy.
Results
Surgical navigation significantly improved accuracy in translational movements along the x-axis (right-left: -0.81 mm; p = 0.021) and z-axis (down-up: -0.82 mm; p = 0.014), as well as in yaw rotation (-0.45°; p = 0.045). Other movements also showed improved precision in the navigated group, though not statistically significant; y-axis (back-front): -0.60 mm ( p = 0.094); pitch rotation: -0.70° ( p = 0.071); roll rotation: -0.04° ( p = 0.428). Besides the use of surgical navigation, the amount of planned movement significantly impacted surgical accuracy, although no specific factors could be identified to predict which cases would particularly benefit from surgical navigation.
Conclusions
Surgical navigation with modified CAD/CAM splints enhances surgical accuracy without requiring invasive procedures, offering a straightforward and transparent protocol suitable for routine clinical practice that allows intraoperative evaluation of maxillary positioning. However, the clinical significance and cost-effectiveness compared to PSI need further investigation. These findings suggest new directions for future developments, especially with advancements in mixed reality technologies, which could broaden the application of surgical navigation.
Trial registration
Retrospectively registered with the German Clinical Trials Register (DRKS00034795).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany.
- Department of Oral and Maxillofacial Surgery, National Dental Centre Singapore, 5 Second Hospital Ave, Singapore, 168938, Singapore.
- Department of Oral and Maxillofacial Surgery, Heinrich Heine University Hospital Düsseldorf, Moorenstraße 5, 40225, Düsseldorf, Germany. Max.Wilkat@med.uni-duesseldorf.de.
Förderung
- Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts
Zitieren
APA
Schrader, F., Saigo, L., Kübler, N., Rana, M., & Wilkat, M. (2025). Novel CAD/CAM-splint-based navigation protocol enhances intraoperative maxillary position control in orthognathic surgery: a case control study. Head & Face Medicine, 21(1). https://doi.org/10.1186/s13005-024-00477-3
Vancouver
Schrader F, Saigo L, Kübler N, Rana M, Wilkat M. Novel CAD/CAM-splint-based navigation protocol enhances intraoperative maxillary position control in orthognathic surgery: a case control study. Head & Face Medicine. 2025;21(1). doi:10.1186/s13005-024-00477-3
BibTeX
@article{Schrader2025,
author = {Schrader, Felix and Saigo, Leonardo and Kübler, Norbert and Rana, Majeed and Wilkat, Max},
title = {Novel CAD/CAM-splint-based navigation protocol enhances intraoperative maxillary position control in orthognathic surgery: a case control study},
journal = {Head & Face Medicine},
year = {2025},
volume = {21},
number = {1},
doi = {10.1186/s13005-024-00477-3}
}
EUVIMED