Surgical accuracy of CAD / CAM splints using virtual surgical planning in orthognathic surgery: policy implications for healthcare in Australia
ANZ Journal of Surgery · 2023-11 · 93 (11) · 2742-2747
DOI: 10.1111/ans.18733 ↗Kurz gefasst
Fachartikel in der Zeitschrift ANZ Journal of Surgery, online erschienen am 23.10.2023. Verfasst von Seth Navinda Delpachitra und 1 weiteren Autor:innen. Beteiligte Einrichtung: Oral and Maxillofacial Surgery, Faculty of Medicine Dentistry and Health Sciences, The University of Melbourne, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Orthognathic Surgery, Orthognathic Surgical Procedures, Surgery, Computer-Assisted. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian and New Zealand Association of Oral and Maxillofacial Surgeons (ANZAOMS) Research and Education Grant.
Abstract (Originalsprache)
Background
This study examines post‐surgical outcomes of maxillary position using virtual surgical planning (VSP) with computer designed and manufactured surgical splints, without the use of costly patient specific implants (PSI), in the treatment of routine nonsyndromic orthognathic patients. The cost of these personalized medical devices and their impact in the setting of cranio‐maxillofacial surgery is currently under review by The Department of Health and Aged Care in Australia.
Methods
This is a single‐centre retrospective analysis of 49 patients who underwent bimaxillary orthognathic surgery by a single surgeon at Epworth Richmond Hospital (Victoria, Australia) over a period spanning 2016 to 2020. Patients were included in the study provided their surgery was facilitated using VSP with manufacture of computer designed occlusal splints.
Results
Use of computer designed and manufactured splints were highly reliable in reproducing the virtual surgical plan, when using palatal plane, upper incisor angulation, and anterior upper facial height.
Conclusion
Use of computer designed and manufactured splints provide a method of leveraging the accuracy of VSP methods, without the additional costs associated with PSI. These findings may assist in appropriate resource allocation and case stratification in patients undergoing orthognathic surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Oral and Maxillofacial Surgery, Faculty of Medicine Dentistry and Health Sciences, The University of Melbourne, Melbourne, Victoria, Australia.
- Oral and Craniomaxillofacial Surgery, Epworth Richmond Hospital, Richmond, Victoria, Australia.
ORCID-Profile: Seth Navinda Delpachitra
Förderung
- Australian and New Zealand Association of Oral and Maxillofacial Surgeons (ANZAOMS) Research and Education Grant
Zitieren
APA
Delpachitra, S. N., & Bordbar, P. (2023). Surgical accuracy of CAD / CAM splints using virtual surgical planning in orthognathic surgery: policy implications for healthcare in Australia. ANZ Journal of Surgery, 93(11), 2742-2747. https://doi.org/10.1111/ans.18733
Vancouver
Delpachitra SN, Bordbar P. Surgical accuracy of CAD / CAM splints using virtual surgical planning in orthognathic surgery: policy implications for healthcare in Australia. ANZ Journal of Surgery. 2023;93(11):2742-2747. doi:10.1111/ans.18733
BibTeX
@article{Delpachitra2023,
author = {Delpachitra, Seth Navinda and Bordbar, Patrishia},
title = {Surgical accuracy of CAD / CAM splints using virtual surgical planning in orthognathic surgery: policy implications for healthcare in Australia},
journal = {ANZ Journal of Surgery},
year = {2023},
volume = {93},
number = {11},
pages = {2742--2747},
doi = {10.1111/ans.18733}
}
EUVIMED