Built-in thiol mesoporous carbon immunosensor to detect carcinoembryonic antigen in human serum
Microchimica Acta · 2026
DOI: 10.1007/s00604-026-07987-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Danilo Echeverri und 5 weiteren Autor:innen. Beteiligte Einrichtung: Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta …. Hauptthemen laut MEDLINE: Carcinoembryonic Antigen, Carbon, Sulfhydryl Compounds, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Antioquia.
Abstract (Originalsprache)
A label-free electrochemical immunosensor for carcinoembryonic antigens (CEA) detection is reported based on a built-in thiol-mesoporous carbon architecture. The material was functionalized with 3-maleimidepropionic acid to immobilize anti-CEA antibodies. The immunosensor was characterized using field-emission scanning electron microscopy, X-ray photoelectron spectroscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Biorecognition events were monitored by differential pulse voltammetry, with current intensity dependent on protein concentration. The device exhibited a linear range of 1–10 ng mL-1 for CEA, with a clinically relevant limit of detection of 1.02 ng mL-1. The immunosensor successfully detected CEA in human serum samples, with results comparable to those obtained by a standard spectrophotometric method. This platform has proven to be a promising alternative for the prognosis and management of patients with colorectal cancer, as well as having significant potential for point-of-care diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia. grupo.tandemnanobioe…
- Grupo Química Básica, Aplicada y Ambiente-Alquimia, Facultad de Ciencias Exactas y Aplicadas, Instituto Tecnológico Metropolitano de Medellín-ITM, Carrera 31 # 54-10, Medellín, 050034, Colombia.
- Clinical Oncology Group, Colombian Cancer Foundation, Clinica Vida, Avenida 33 #63A- 18, Medellín, 050030, Colombia.
- Química de Recursos Energéticos y Medio Ambiente, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Calle 70 No. 52-21, Medellín, 050010, Colombia.
- Max Planck Tandem Group in Nanobioengineering, Institute of Chemistry, Faculty of Natural and Exact Sciences, University of Antioquia, Complejo Ruta N, Calle 67 N° 52-20, Medellín, 050010, Colombia.
Förderung
- University of Antioquia
Zitieren
APA
Echeverri, D., Laverde, J., Restrepo, L. G., Llinás-Quintero, N., López, D., & Orozco, J. (2026). Built-in thiol mesoporous carbon immunosensor to detect carcinoembryonic antigen in human serum. Microchimica Acta. https://doi.org/10.1007/s00604-026-07987-8
Vancouver
Echeverri D, Laverde J, Restrepo LG, Llinás-Quintero N, López D, Orozco J. Built-in thiol mesoporous carbon immunosensor to detect carcinoembryonic antigen in human serum. Microchimica Acta. 2026. doi:10.1007/s00604-026-07987-8
BibTeX
@article{Echeverri2026,
author = {Echeverri, Danilo and Laverde, Jennifer and Restrepo, Luis Gerónimo and Llinás-Quintero, Nestor and López, Diana and Orozco, Jahir},
title = {Built-in thiol mesoporous carbon immunosensor to detect carcinoembryonic antigen in human serum},
journal = {Microchimica Acta},
year = {2026},
doi = {10.1007/s00604-026-07987-8}
}
EUVIMED