An intense cathodic electrochemiluminescence from carbon-nanosheets in situ grown on glassy carbon electrode and application in immunoanalysis via biometallization strategy
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06624-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Xifeng Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014, People's Republic of China. Hauptthemen laut MEDLINE: Carbon, Electrodes, Luminescent Measurements, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
An intense cathodic electrochemiluminescence (ECL) is reported from a polarized glassy carbon electrode (GCE) in peroxydisulfate solution. After the polarization in 1 M Na2SO4 at the potential of - 3.7 V for 3 s, carbon nanosheets (C-NSs) were in situ grown on the surface of the GCE. Measured in 100 mM K2S2O8 solution, the ECL intensity of the GCE/C-NSs is 112-fold that of a bare GCE. The ECL spectrum revealed that the true ECL luminophore in the GCE/C-NSs-peroxydisulfate system is O2/S2O82- which is promoted by C-NSs. When Cu2+ was electrochemically enriched and reduced to Cu(0) on the catalytic sites of C-NSs, the ECL from GCE/C-NSs/Cu in K2S2O8 solution was decreased with increasing logarithmic concentration of Cu2+ in the range from 10 pM to 1 μM, with a limit of detection (LOD) of 3 pM. An immunoanalysis method is proposed via a biometallization strategy using CuS nanoparticles as the tags and carcinoembryonic antigen (CEA) as the model analyte. After the immune recognition in the microplate, the CuS tags in the immunocomplex were dissolved and the resultant Cu2+ was electrochemically enriched and reduced on the catalytic sites of C-NSs, quenching the ECL intensity of GCE/C-NSs-O2/S2O82- system. The proposed ECL immunoanalysis method was used to quantify CEA in actual serum samples with an LOD of 1.0 fg mL-1, possessing the advantages of simple electrode modification, high sensitivity and good reproducibility.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014, People's Republic of China.
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014, People's Republic of China. dzshen@sdnu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
Zitieren
APA
Yu, X., Shen, Q., Yu, M., Zhang, W., Kang, Q., & Shen, D. (2024). An intense cathodic electrochemiluminescence from carbon-nanosheets in situ grown on glassy carbon electrode and application in immunoanalysis via biometallization strategy. Microchimica Acta. https://doi.org/10.1007/s00604-024-06624-6
Vancouver
Yu X, Shen Q, Yu M, Zhang W, Kang Q, Shen D. An intense cathodic electrochemiluminescence from carbon-nanosheets in situ grown on glassy carbon electrode and application in immunoanalysis via biometallization strategy. Microchimica Acta. 2024. doi:10.1007/s00604-024-06624-6
BibTeX
@article{Yu2024,
author = {Yu, Xifeng and Shen, Qirui and Yu, Miaomiao and Zhang, Wei and Kang, Qi and Shen, Dazhong},
title = {An intense cathodic electrochemiluminescence from carbon-nanosheets in situ grown on glassy carbon electrode and application in immunoanalysis via biometallization strategy},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06624-6}
}
EUVIMED