Coreactant-free and single-potential-channel electrochemiluminescence from dual-thiols-stabilizer capped gold nanoclusters and its NIR immunoassay application
Biosensors and Bioelectronics · 2025-10 · 286 · 117617
DOI: 10.1016/j.bios.2025.117617 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025-10. Verfasst von Mengwei Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, PR China. Hauptthemen laut MEDLINE: Gold, Luminescent Measurements, Biosensing Techniques, Metal Nanoparticles. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: Shandong Province Natural Science Foundation, Jinan Science and Technology Bureau, National Natural Science Foundation of China.
Abstract (Originalsprache)
Ru(bpy)32+/tripropylamine (TPrA) is the sole electrochemiluminescence (ECL) system, which is being extensively employed in commercialized In Vitro Diagnosis. The coreactant ECL of Ru(bpy)32+/TPrA is of a multiple-channel emission and wide electrochemical potential window nature. Herein, a coreactant-free and single-potential-channel ECL strategy is proposed with a biocompatible nano-electrochemiluminophore, i.e., dihydrolipoic acid-capped Au nanoclusters (DHLA-AuNCs) as model, in which the metal-sulfur bonds between two sulfhydryls of DHLA and the Au element enable AuNCs with a S vacancies involved electron-rich and n-type nature for DHLA-AuNCs. The DHLA-AuNCs can be electrochemically oxidized, the annihilation reaction between exogenous holes and endogenous free-electrons can emit a kind of coreactant-free single-potential-channel ECL between +0.70 and + 1.20 V (vs Ag/AgCl) with the maximum emission potential of +0.91 V (vs Ag/AgCl) and the maximum emission wavelength of 778 nm. The ECL can be conveniently achieved, and selectively determine human carcinoembryonic antigen with the linear response range from 20 to 5000 pg/mL and the limit of detection of 5 pg/mL. The coreactant-free and single-potential-channel ECL of DHLA-AuNCs provides an alternative to the coreactant ECL of Ru(bpy)32+/TPrA for less electrochemical-interference and signal-crosstalk.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, PR China.
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, PR China. Electronic address: gaoxuwen@mail.sdu.edu.cn.
- School of Chemistry and Chemical Engineering, Shandong University, Jinan, 250100, PR China. Electronic address: zouguizheng@sdu.edu.cn.
Förderung
- Shandong Province Natural Science Foundation
- Jinan Science and Technology Bureau
- National Natural Science Foundation of China
Zitieren
APA
Li, M., Gao, X., Ren, X., Ma, L., Wang, Y., & Zou, G. (2025). Coreactant-free and single-potential-channel electrochemiluminescence from dual-thiols-stabilizer capped gold nanoclusters and its NIR immunoassay application. Biosensors and Bioelectronics, 286, 117617. https://doi.org/10.1016/j.bios.2025.117617
Vancouver
Li M, Gao X, Ren X, Ma L, Wang Y, Zou G. Coreactant-free and single-potential-channel electrochemiluminescence from dual-thiols-stabilizer capped gold nanoclusters and its NIR immunoassay application. Biosensors and Bioelectronics. 2025;286:117617. doi:10.1016/j.bios.2025.117617
BibTeX
@article{Li2025,
author = {Li, Mengwei and Gao, Xuwen and Ren, Xiaoxuan and Ma, Luyao and Wang, Yujiao and Zou, Guizheng},
title = {Coreactant-free and single-potential-channel electrochemiluminescence from dual-thiols-stabilizer capped gold nanoclusters and its NIR immunoassay application},
journal = {Biosensors and Bioelectronics},
year = {2025},
volume = {286},
pages = {117617},
doi = {10.1016/j.bios.2025.117617}
}
EUVIMED