Ultra-sensitive fluorescent biosensor for multiple bacteria detection based on CDs/QDs@ZIF-8 and microfluidic fluidized bed
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06303-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Fengchun Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Biochemical Engineering, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Proces…. Hauptthemen laut MEDLINE: Quantum Dots, Zeolites, Escherichia coli O157, Biosensing Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China Youth Science Fund Project.
Abstract (Originalsprache)
An ultra-sensitive fluorescent biosensor based on CDs/QDs@ZIF-8 and microfluidic fluidized bed was developed for rapid and ultra-sensitive detection of multiple target bacteria. The zeolitic imidazolate frameworks (ZIF-8) act as the carrier to encapsulate three kinds of fluorescence signal molecules from the CDs/QDs@ZIF-8 signal amplification system. Besides, three kinds of target pathogenic bacteria were automatically, continuously, and circularly captured by the magnetic nanoparticles (MNPs) in the microfluidic fluidized bed. The neutral Na2EDTA solution was the first time reported to not only dissolve the ZIF-8 frameworks from the MNPs-bacteria-CDs/QDs@ZIF-8 sandwich complexes, but also release the CDs/QDs from sandwich complexes with no loss of fluorescence signal. Due to the advantages of signal amplification and automated sample pretreatment, the proposed fluorescent biosensor can simultaneously detect Escherichia coli O157:H7, Salmonella paratyphi A, and Salmonella paratyphi B as low as 101 CFU/mL within 1.5 h, respectively. The mean recovery in spiked milk samples can reach 99.18%, verifying the applicability of this biosensor in detecting multiple bacteria in real samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- National Key Laboratory of Biochemical Engineering, PLA Key Laboratory of Biopharmaceutical Production & Formulation Engineering, Institute of Process Engineering, Chinese Academy of Sciences, Beijing, 100190, People's…
- Innovation Academy for Green Manufacture Institute, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China.
- Institute of Agro-Product Quality and Safety, of Quality Standard & Testing Technology for Agro-Products, Key Laboratory, Chinese Academy of Agricultural Sciences, Beijing, 100081, China.
- University of Chinese Academy of Sciences, Beijing, 100049, People's Republic of China.
- Biosafety Research Center Yangtze River Delta in Zhangjiagang, Suzhou, 215611, People's Republic of China.
- Innovation Academy for Green Manufacture Institute, Chinese Academy of Sciences, Beijing, 100190, People's Republic of China. zhoulei17@ipe.ac.cn.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China Youth Science Fund Project
Zitieren
APA
Huang, F., Sun, C., Dong, J., Wu, X., Du, Y., Hu, Q., & Zhou, L. (2024). Ultra-sensitive fluorescent biosensor for multiple bacteria detection based on CDs/QDs@ZIF-8 and microfluidic fluidized bed. Microchimica Acta. https://doi.org/10.1007/s00604-024-06303-6
Vancouver
Huang F, Sun C, Dong J, Wu X, Du Y, Hu Q, et al. Ultra-sensitive fluorescent biosensor for multiple bacteria detection based on CDs/QDs@ZIF-8 and microfluidic fluidized bed. Microchimica Acta. 2024. doi:10.1007/s00604-024-06303-6
BibTeX
@article{Huang2024,
author = {Huang, Fengchun and Sun, Chongsi and Dong, Jinying and Wu, Xiaoya and Du, Yuguang and Hu, Qiushi and Zhou, Lei},
title = {Ultra-sensitive fluorescent biosensor for multiple bacteria detection based on CDs/QDs@ZIF-8 and microfluidic fluidized bed},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06303-6}
}
EUVIMED