EUVIMEDEUVIMED entdecken
Crossref

Ratiometric Biomimetic Sensor Based on Quantum Dots–Enhanced Glycosylated Carbon Dots for Visual Detection of Escherichia coli

Fatemeh Momeni, Saba Ranjbar iD, Mohammad Amin Farahmand Nejad, Mohammad Reza Hormozi-Nezhad iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.5c06000 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Fatemeh Momeni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Energy and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 14965/161, Iran. Hauptthemen laut MEDLINE: Quantum Dots, Carbon, Biosensing Techniques, Escherichia coli O157. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Institute for Genetic Engineering and Biotechnology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We report a fluorescence biomimetic sensor that integrates carbon dots (CDs) and CdTe quantum dots (QDs) for the rapid, antibody-free, and aptamer-free detection of Escherichia coli O157:H7 (E. coli O157:H7) in water samples. This biosensor operates on a ratiometric principle, leveraging green-emitting CDs (GCDs) as a dynamic signal with the red-emitting QDs (RQDs) as a stable reference that significantly enhances the sensor's sensitivity, enabling straightforward visual detection of bacterial contamination. Selectivity was achieved by conjugating mannose─a natural biomimetic receptor─ to GCDs, allowing specific recognition of FimH proteins on E. coli O157:H7. Upon bacterial binding, the green emission at 508 nm intensifies proportionally to bacterial concentration, while the red fluorescence at 694 nm remains unchanged. This ratiometric biomimetic sensor detects bacterial concentrations ranging from 101 to 108 CFU/mL within 30 min. The biosensor provides a simple, on-site, naked-eye detection under a portable blue-LED light, with color changes indicating water safety status: green for high bacterial loads, yellow/orange for moderate contamination, and red for safe water. It was successfully applied to tap water, bottled mineral water, surface and groundwater, as well as to samples collected at multiple stages of water treatment plants (12 sources; five replicates). Comprehensive characterization of the nanomaterials was performed using Fourier-transform infrared spectroscopy (FTIR), UV-vis absorption, fluorescence spectroscopy, transmission electron microscopy (TEM), dynamic light scattering (DLS), and zeta potential analysis. This portable, cost-effective biomimetic sensor provides a rapid, reliable alternative to conventional microbiological methods for monitoring drinking water.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Quantum DotsCarbonBiosensing TechniquesEscherichia coli O157BiomimeticsBiomimetic MaterialsTelluriumCadmium CompoundsAdhesins, Escherichia coliFimbriae Proteins

Substanzen

CarbonTelluriumCadmium Compoundscadmium telluridefimH protein, E coliAdhesins, Escherichia coliFimbriae Proteins

Autor:innen und Institutionen

  • Department of Energy and Environmental Biotechnology, National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran 14965/161, Iran.
  • Department of Chemistry, Sharif University of Technology, Tehran 11155-9516, Iran.

ORCID-Profile: Saba Ranjbar, Mohammad Reza Hormozi-Nezhad

Förderung

  • National Institute for Genetic Engineering and Biotechnology

Zitieren

APA

Momeni, F., Ranjbar, S., Farahmand Nejad, M. A., & Hormozi-Nezhad, M. R. (2026). Ratiometric Biomimetic Sensor Based on Quantum Dots–Enhanced Glycosylated Carbon Dots for Visual Detection of Escherichia coli. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c06000

Vancouver

Momeni F, Ranjbar S, Farahmand Nejad MA, Hormozi-Nezhad MR. Ratiometric Biomimetic Sensor Based on Quantum Dots–Enhanced Glycosylated Carbon Dots for Visual Detection of Escherichia coli. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c06000

BibTeX
@article{Momeni2026,
  author = {Momeni, Fatemeh and Ranjbar, Saba and Farahmand Nejad, Mohammad Amin and Hormozi-Nezhad, Mohammad Reza},
  title = {Ratiometric Biomimetic Sensor Based on Quantum Dots–Enhanced Glycosylated Carbon Dots for Visual Detection of Escherichia coli},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.5c06000}
}
Kostenlos starten →