Engineered CdS@ZIF67 nanozyme-assisted detection of vitamin D deficiency

Anna Anandita, Dharitri Rath, Premveer Singh, Prakash Kumar Pathak, Rahul R Salunkhe

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2026.118379 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Anna Anandita und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Indian Institute of Technology, Jammu, Jammu and Kashmir, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Cadmium Compounds, Metal-Organic Frameworks, Quantum Dots. Die Arbeit nennt 48 Literaturangaben. Gefördert von: Indian Institute of Technology Jammu.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peroxidases are natural enzymes commonly employed in developing sensitive immunoassays; however, their limited stability has sparked growing interest in enzyme-mimics. Zeolitic imidazolate frameworks (ZIFs), a subclass of metal-organic frameworks (MOFs), are promising alternatives due to their ease of synthesis, tunable porosity, multiple active sites, and robust catalytic properties. In the current work, we synthesized and characterized CdS@ZIF67, which is a nanocomposite of CdS quantum dots and ZIF-67, exhibiting peroxidase-like activity. Catalytic performance was then examined using Michaelis-Menten kinetics, with estimated key parameters (kcat, Km, and catalytic efficiency kcat/Km) benchmarked against natural Horseradish Peroxidase (HRP) enzyme. It showed an increase in catalytic efficiency of the order 103 as compared to ZIF 67, and a comparable catalytic efficiency with that of HRP. To demonstrate its biosensing ability, we further conjugated it to anti-vitamin D3 antibodies and implemented this for sensing vitamin D3 molecules in a competitive dipstick format. Here, the nanozymes catalyzed a clear colorimetric response for clinically relevant concentrations of vitamin D3 in the presence of TMB and H2O2, with a limit of detection (LOD) of 26.98 ng/ml, and a LOD of 24.93 ng/ml in spiked serum samples. Our assays could reliably distinguish between deficiency and sufficiency of vitamin D3. This study provides valuable insights into nanozyme design and mimetic function, emphasizing the promising role of CdS@ZIF67 nanozymes as substitutes for natural enzymes in biosensing applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesCadmium CompoundsMetal-Organic FrameworksQuantum DotsSulfidesZeolitesHumansLimit of DetectionColorimetryNanocomposites

Stichwörter der Autor:innen

BiosensingCdS@ZIF67Competitive immunoassayEnzyme kineticsNanozyme

Substanzen

Cadmium CompoundsMetal-Organic FrameworksSulfidescadmium sulfideZeolites

Autor:innen und Institutionen

  • Department of Chemical Engineering, Indian Institute of Technology, Jammu, Jammu and Kashmir, India.
  • Department of Chemical Engineering, Indian Institute of Technology, Jammu, Jammu and Kashmir, India. Electronic address: dharitri.rath@iitjammu.ac.in.
  • Department of Physics, Indian Institute of Technology, Jammu, Jammu and Kashmir, India.

Förderung

  • Indian Institute of Technology Jammu

Zitieren

APA

Anandita, A., Rath, D., Singh, P., Pathak, P. K., & Salunkhe, R. R. (2026). Engineered CdS@ZIF67 nanozyme-assisted detection of vitamin D deficiency. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2026.118379

Vancouver

Anandita A, Rath D, Singh P, Pathak PK, Salunkhe RR. Engineered CdS@ZIF67 nanozyme-assisted detection of vitamin D deficiency. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2026.118379

BibTeX
@article{Anandita2026,
  author = {Anandita, Anna and Rath, Dharitri and Singh, Premveer and Pathak, Prakash Kumar and Salunkhe, Rahul R},
  title = {Engineered CdS@ZIF67 nanozyme-assisted detection of vitamin D deficiency},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2026.118379}
}
Kostenlos starten →