EUVIMEDEUVIMED entdecken
Crossref

An antifouling electrochemical biosensor based on chondroitin sulfate-functionalized polyaniline and DNA-peptide conjugates for cortisol determination in body fluids

Keke Xu, Jincheng Yang, Liwei Shen, Xinhui Wang, Ni Hui, Jiasheng Wang

Microchimica Acta · 2023-12 · 190 (12)

DOI: 10.1007/s00604-023-06083-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 01.12.2023. Verfasst von Keke Xu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Qingdao Agricultural University, Qingdao, People's Republic of China. Hauptthemen laut MEDLINE: Biofouling, Body Fluids, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An antifouling electrochemical biosensor was constructed based on chondroitin sulfate (CS)-functionalized polyaniline (CS/PANI) and DNA-peptide conjugates that is capable of assaying cortisol directly in human fluids. First, a CS-doped PANI nanocomposite (sensing substrate) was electrodeposited onto a bare glassy carbon electrode to promote electron transport, providing the sensing signal from high peak currents of PANI to improve the sensitivity of the biosensor. Dendritic DNA-peptide conjugates were assembled onto the CS/PANI by exploiting the highly specific and strong interactions between biotin and streptavidin, which amplified the sensing signals toward cortisol. The integration of the DNA-peptide conjugates into the CS/PANI nanocomposite ensured that the biosensor had a synergistic antifouling effect and was capable of detecting cortisol directly in body fluids (sweat, saliva, and tears). When assaying cortisol levels, the biosensor exhibited a linear range over the cortisol concentrations of 1 × 10-12-1 × 10-7 M and a low limit of detection (0.333 × 10-12 M). In the detection of cortisol in real samples, the relative standard deviation (RSD) of the biological samples ranged from 2.94 to 4.23%, and the recovery were calculated to be in the range 95.2-103.2%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiofoulingBody FluidsBiosensing TechniquesHumansHydrocortisoneChondroitin SulfatesDNAPeptidesAniline Compounds

Stichwörter der Autor:innen

AntifoulingBiosensorChondroitin sulfateCortisolDNA-peptide conjugateDifferential pulse voltammetryModified electrodePolyaniline

Substanzen

HydrocortisoneChondroitin SulfatesDNAPeptidespolyanilineAniline Compounds

Autor:innen und Institutionen

  • Qingdao Agricultural University, Qingdao, People's Republic of China.
  • Oncology Department, Qingdao Women and Children Hospital, Qingdao, People's Republic of China.
  • Ocean University of China, Qingdao, People's Republic of China.
  • Qingdao Agricultural University, Qingdao, People's Republic of China. huini1029@163.com.
  • Qingdao Agricultural University, Qingdao, People's Republic of China. jiasheng0813@163.com.

Zitieren

APA

Xu, K., Yang, J., Shen, L., Wang, X., Hui, N., & Wang, J. (2023). An antifouling electrochemical biosensor based on chondroitin sulfate-functionalized polyaniline and DNA-peptide conjugates for cortisol determination in body fluids. Microchimica Acta, 190(12). https://doi.org/10.1007/s00604-023-06083-5

Vancouver

Xu K, Yang J, Shen L, Wang X, Hui N, Wang J. An antifouling electrochemical biosensor based on chondroitin sulfate-functionalized polyaniline and DNA-peptide conjugates for cortisol determination in body fluids. Microchimica Acta. 2023;190(12). doi:10.1007/s00604-023-06083-5

BibTeX
@article{Xu2023,
  author = {Xu, Keke and Yang, Jincheng and Shen, Liwei and Wang, Xinhui and Hui, Ni and Wang, Jiasheng},
  title = {An antifouling electrochemical biosensor based on chondroitin sulfate-functionalized polyaniline and DNA-peptide conjugates for cortisol determination in body fluids},
  journal = {Microchimica Acta},
  year = {2023},
  volume = {190},
  number = {12},
  doi = {10.1007/s00604-023-06083-5}
}
Kostenlos starten →