Design of U-shaped peptides with long-lasting antifouling efficacy: Toward a feasible electrochemical aptasensor for robust detection in human serum
Analytica Chimica Acta · 2024
DOI: 10.1016/j.aca.2024.342953 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytica Chimica Acta, 2024. Verfasst von Yanxin Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of …. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biosensing Techniques, Peptides, Gold. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
BACKGROUND: Developing biosensors with antifouling properties is essential for accurately detecting low-concentration biomarkers in complex biological matrix, which is imperative for effective disease diagnosis and treatment. Herein, an antifouling electrochemical aptasensor qualifying for probing targets in human serum was explored based on newly-devised peptides that could form inverted U-shaped structures with long-term stability. RESULTS: The inverted U-shaped peptides (U-Pep) with two terminals of thiol groups grafted onto the Au-modified electrode showcase superior antifouling properties in terms of high stability against enzymatic hydrolysis and long acting against biofouling in actual biofluids. The construction of the outlined antifouling electrochemical aptasensor just involved the fabrication of Au-deposited poly(3,4 ethylenedioxythiophene) (Au/PEDOT) modified electrode, followed by one-step co-incubation in the peptides and the aptamer probes with the Au/PEDOT electrode. Taking a typical biomarker of alpha-fetoprotein (AFP) for detection, this elegant antifouling aptasenor demonstrated a nice response for probing the target AFP with a low detection limit of 0.27 pg/mL and a wide linear scope of 1.0 pg/mL to 1.0 μg/mL, and furthermore qualified for assaying of AFP in human serum samples with satisfactory accuracy and feasibility. SIGNIFICANCE: This engineering strategy of U-Pep with long-lasting antifouling efficacy opens a new horizon for high-performance antifouling biosensors suitable for detection in complex bifluids, and it could spark more inspiration for a follow-up exploration of other featured antifouling biomaterials.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Optic-Electric Sensing and Analytical Chemistry for Life Science, MOE, Shandong Key Laboratory of Biochemical Analysis, College of Chemistry and Molecular Engineering, Qingdao University of Science and…
Förderung
- Natural Science Foundation of Shandong Province
- National Natural Science Foundation of China
Zitieren
APA
Li, Y., Wei, Z., Guo, S., Zhan, Y., Fan, G. C., & Luo, X. (2024). Design of U-shaped peptides with long-lasting antifouling efficacy: Toward a feasible electrochemical aptasensor for robust detection in human serum. Analytica Chimica Acta. https://doi.org/10.1016/j.aca.2024.342953
Vancouver
Li Y, Wei Z, Guo S, Zhan Y, Fan GC, Luo X. Design of U-shaped peptides with long-lasting antifouling efficacy: Toward a feasible electrochemical aptasensor for robust detection in human serum. Analytica Chimica Acta. 2024. doi:10.1016/j.aca.2024.342953
BibTeX
@article{Li2024,
author = {Li, Yanxin and Wei, Zhen and Guo, Shuyue and Zhan, Yinan and Fan, Gao-Chao and Luo, Xiliang},
title = {Design of U-shaped peptides with long-lasting antifouling efficacy: Toward a feasible electrochemical aptasensor for robust detection in human serum},
journal = {Analytica Chimica Acta},
year = {2024},
doi = {10.1016/j.aca.2024.342953}
}
EUVIMED