Electrochemical sensors for cortisol detection: Principles, designs, fabrication, and characterisation
Biosensors and Bioelectronics · 2023-11 · 239 · 115600
DOI: 10.1016/j.bios.2023.115600 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors and Bioelectronics, 2023-11. Verfasst von Gopi Karuppaiah und 3 weiteren Autor:innen. Beteiligte Einrichtung: Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, 630 003, Tamil Nadu, India; School of …. Hauptthemen laut MEDLINE: Biosensing Techniques, Biofouling. Die Arbeit wurde bisher 79-mal zitiert (Crossref) und nennt 218 Literaturangaben. Gefördert von: Defence Research and Development Organisation.
Abstract (Originalsprache)
Psychological stress is a major factor contributing to health discrepancies among individuals. Sustained exposure to stress triggers signalling pathways in the brain, which leading to the release of stress hormones in the body. Cortisol, a steroid hormone, is a significant biomarker for stress management due to its responsibility in the body's reply to stress. The release of cortisol in bloodstream prepares the body for a "fight or flight" response by increasing heart rate, blood pressure, metabolism, and suppressing the immune system. Detecting cortisol in biological samples is crucial for understanding its role in stress and personalized healthcare. Traditional techniques for cortisol detection have limitations, prompting researchers to explore alternative strategies. Electrochemical sensing has emerged as a reliable method for point-of-care (POC) cortisol detection. This review focuses on the progress made in electrochemical sensors for cortisol detection, covering their design, principle, and electroanalytical methodologies. The analytical performance of these sensors is also analysed and summarized. Despite significant advancements, the development of electrochemical cortisol sensors faces challenges such as biofouling, sample preparation, sensitivity, flexibility, stability, and recognition layer performance. Therefore, the need to develop more sensitive electrodes and materials is emphasized. Finally, we discussed the potential strategies for electrode design and provides examples of sensing approaches. Moreover, the encounters of translating research into real world applications are addressed.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, 630 003, Tamil Nadu, India; School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak…
- School of Integrative Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Republic of Korea.
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL, 33174, USA. Electronic address: sbhansa@fiu.edu.
- Electrodics and Electrocatalysis Division, CSIR-Central Electrochemical Research Institute (CECRI), Karaikudi, 630 003, Tamil Nadu, India; Academy of Scientific and Innovative Research, Ghaziabad, 201 002, Uttar Pradesh…
Förderung
- Defence Research and Development Organisation
Zitieren
APA
Karuppaiah, G., Lee, M. H., Bhansali, S., & Manickam, P. (2023). Electrochemical sensors for cortisol detection: Principles, designs, fabrication, and characterisation. Biosensors and Bioelectronics, 239, 115600. https://doi.org/10.1016/j.bios.2023.115600
Vancouver
Karuppaiah G, Lee MH, Bhansali S, Manickam P. Electrochemical sensors for cortisol detection: Principles, designs, fabrication, and characterisation. Biosensors and Bioelectronics. 2023;239:115600. doi:10.1016/j.bios.2023.115600
BibTeX
@article{Karuppaiah2023,
author = {Karuppaiah, Gopi and Lee, Min-Ho and Bhansali, Shekhar and Manickam, Pandiaraj},
title = {Electrochemical sensors for cortisol detection: Principles, designs, fabrication, and characterisation},
journal = {Biosensors and Bioelectronics},
year = {2023},
volume = {239},
pages = {115600},
doi = {10.1016/j.bios.2023.115600}
}
EUVIMED