Polyester resin and graphite flakes: turning conductive ink to a voltammetric sensor for paracetamol sensing
Microchimica Acta · 2023
DOI: 10.1007/s00604-023-05914-9 ↗At a glance
Journal article in Microchimica Acta, 2023. Written by Laísa C Oliveira and 4 co-authors. Institution: Faculdade de Farmácia, Universidade Federal de Goiás, Goiânia, GO, 74605-170, Brazil. Major MEDLINE topics: Acetaminophen, Graphite. Cited 11 times so far (Crossref); 51 references. Funded by: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (original language)
The development of a disposable electrochemical paper-based analytical device (ePAD) is described using a novel formulation of conductive ink that combines graphite powder, polyester resin, and acetone. As a proof of concept, the proposed sensor was utilized for paracetamol (PAR) sensing. The introduced ink was characterized via morphological, structural, and electrochemical analysis, and the results demonstrated appreciable analytical performance. The proposed ePAD provided linear behavior (R2 = 0.99) in the concentration range between 1 and 60 µmol L-1, a limit of detection of 0.2 µmol L-1, and satisfactory reproducibility (RSD ~ 7.7%, n = 5) applying a potential of + 0.81 V vs Ag at the working electrode. The quantification of PAR was demonstrated in different pharmaceutical formulations. The achieved concentrations revealed good agreement with the labeled values, acceptable accuracy (101% and 106%), and no statistical difference from the data obtained by HPLC at the 95% confidence level. The environmental impact of the new device was assessed using AGREE software, which determined a score of 0.85, indicating that it is eco-friendly. During the pharmacokinetic study of PAR, it was found that the drug has a maximum concentration of 23.58 ± 0.01 µmol L-1, a maximum time of 30 min, and a half-life of 2.15 h. These results are comparable to other studies that utilized HPLC. This suggests that the combination of graphite powder and polyester resin can transform conductive ink into an effective ePAD that can potentially be used in various pharmaceutical applications.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Faculdade de Farmácia, Universidade Federal de Goiás, Goiânia, GO, 74605-170, Brazil.
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, 74690-900, Brazil.
- Instituto de Ciências Farmacêuticas, Goiânia, GO, 74175-100, Brazil.
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO, 74690-900, Brazil. wendell@ufg.br.
- Instituto Nacional de Ciência E Tecnologia de Bioanalítica, Campinas, SP, 13084-971, Brazil. wendell@ufg.br.
Funding
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Instituto Nacional de Ciência e Tecnologia de Bioanalítica
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Cite
APA
Oliveira, L. C., Rocha, D. S., Silva-Neto, H. A., Silva, T. A. C., & Coltro, W. K. T. (2023). Polyester resin and graphite flakes: turning conductive ink to a voltammetric sensor for paracetamol sensing. Microchimica Acta. https://doi.org/10.1007/s00604-023-05914-9
Vancouver
Oliveira LC, Rocha DS, Silva-Neto HA, Silva TAC, Coltro WKT. Polyester resin and graphite flakes: turning conductive ink to a voltammetric sensor for paracetamol sensing. Microchimica Acta. 2023. doi:10.1007/s00604-023-05914-9
BibTeX
@article{Oliveira2023,
author = {Oliveira, Laísa C and Rocha, Danielly S and Silva-Neto, Habdias A and Silva, Thaísa A C and Coltro, Wendell K T},
title = {Polyester resin and graphite flakes: turning conductive ink to a voltammetric sensor for paracetamol sensing},
journal = {Microchimica Acta},
year = {2023},
doi = {10.1007/s00604-023-05914-9}
}
EUVIMED