Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-023-05009-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Thalles Pedrosa Lisboa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil. thalleslisboa@ufgd.edu.br. Hauptthemen laut MEDLINE: Acetaminophen, Graphite. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 72 Literaturangaben. Gefördert von: Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
In this work, we are pleased to present for the first time a 3D-printed electrochemical device using a lab-made conductive filament based on graphite (Gr) and polylactic acid (PLA) polymer matrix for the simultaneous detection of amoxicillin (AMX) and paracetamol (PAR). The sensor was properly characterized by scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS), and cyclic voltammetry (CV). Compared to the commercial glassy carbon electrode (GCE), the superior performance of the 3D-Gr/PLA electrode was verified with a 3.8-fold more favored charge transfer. A differential pulse voltammetry (DPV) method was proposed providing a linear working range of 4 to 12 μmol L-1 for both analytes and a limit of detection (LOD) of 0.80 and 0.51 μmol L-1 for AMX and PAR, respectively. Additionally, repeatability studies (n = 5, RSD < 5.7%) indicated excellent precision, and recovery percentages ranging from 89 to 109% when applied to synthetic human urine, saliva, and plasma samples, attested to the accuracy of the method. The studies also indicate that the sensor does not suffer significant interference from common substances (antibiotics and biomarkers) present in the biological fluids, which makes it a promising analytical tool considering its low-cost, ease of manufacturing, robustness, and electrochemical performance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil. thalleslisboa@ufgd.edu.br.
- FACET, Great Dourados Federal University, Dourados, 79804-970, Brazil. thalleslisboa@ufgd.edu.br.
- Chemistry Institute, Fluminense Federal University, Niterói, 24220-900, Brazil.
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil.
- Chemistry Department, Federal University of Juiz de Fora, Juiz de Fora, 36036-900, Brazil. renato.matos@ufjf.edu.br.
Förderung
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Lisboa, T. P., de Faria, L. V., de Oliveira, W. B. V., Oliveira, R. S., de Souza, C. C., Matos, M. A. C., Dornellas, R. M., & Matos, R. C. (2024). Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-05009-7
Vancouver
Lisboa TP, de Faria LV, de Oliveira WBV, Oliveira RS, de Souza CC, Matos MAC, et al. Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-023-05009-7
BibTeX
@article{Lisboa2024,
author = {Lisboa, Thalles Pedrosa and de Faria, Lucas Vinícius and de Oliveira, Wallace Burger Veríssimo and Oliveira, Raylla Santos and de Souza, Cassiano Cunha and Matos, Maria Auxiliadora Costa and Dornellas, Rafael Machado and Matos, Renato Camargo},
title = {Simultaneous monitoring of amoxicillin and paracetamol in synthetic biological fluids using a 3D printed disposable electrode with a lab-made conductive filament},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-023-05009-7}
}
EUVIMED