EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Computer modeling and validation testing for glenoid component rotation and optimal glenoid screw angles for reverse shoulder arthroplasty in an Asian population

Shun Sing Martin Cheng, Colin Shing-Yat Yung, Samuel De Hoi Wong, Christopher Chun Hei Yip, Issac Jun Ren Khoo, Tsoi Wan Karen Wong, Christian Fang

International Orthopaedics · 2024

DOI: 10.1007/s00264-024-06340-z ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift International Orthopaedics, 2024. Verfasst von Shun Sing Martin Cheng und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics of Traumatology, Queen Mary Hospital, Pokfulam, Hong Kong. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Bone Screws, Shoulder Joint, Scapula. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Good initial fixation of glenoid component for reverse total shoulder arthroplasty (RTSA) relies on component placement and screw purchase in the scapula bone. This is especially difficult in an Asian population with small glenoid geometry. Optimal glenoid component roll angle and screw angulation to achieve the longest screws for best fixation has not been defined in the current literature.

Methods

Computer 3D modelling of 133 scapulas with RTSA performed were analyzed to determine patient specific optimal glenoid roll angle (GRA) for the longest bi-cortical screws attainable. The cranial-caudal angle (CCA), anterior-posterior angle (APA) and lengths for the superior and inferior screws were measured. Validation testing using calculated average (CA) angles and rounded average (RA) angles to the nearest 5 degree were recomputed for each case to determine the bi-cortical screw lengths achievable. The CA and RA screw lengths were compared against patient specific modelling using paired-sample t-tests.

Results

Average GRA was − 1.6°, almost perpendicular to the long axis of the glenoid and achieves an average bi-cortical screw length of 51.3 mm and 45.5 mm for the superior and inferior screws respectively. The CCA and APA were 9.1° cranial and 6.5° posterior for the superior screw and screw angulation of 11.2° caudal and 0.7° anterior for the inferior screw. Validation testing shows statistically shorter screw lengths in the CA and RA models compared to patient specific modelling ( p < 0.01).

Conclusion

Validation testing with average angles for GRA, CCA and APA demonstrates strong patient heterogeneity and anatomical variation. Despite this, screw lengths attainable in the RA group were > 38 mm with good safety profile. Surgeons may consider the additional use of navigation-assisted, or 3D printed patient specific instrumentation to optimize baseplate and screw configuration for RTSA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderBone ScrewsShoulder JointScapulaAsian PeopleHumansFemaleMaleAgedImaging, Three-DimensionalMiddle AgedComputer SimulationRotationGlenoid CavityAdultShoulder Prosthesis

Stichwörter der Autor:innen

3D modellingGlenoid fixationPatient specific instrumentationReverse shoulder arthroplastyScrew length

Autor:innen und Institutionen

  • Department of Orthopaedics of Traumatology, Queen Mary Hospital, Pokfulam, Hong Kong.
  • Li Ka Shing Faculty of Medicine, The University of Hong Kong, Pokfulam, Hong Kong.
  • Department of Orthopaedics and Traumatology, The University of Hong Kong, Pokfulam, Hong Kong. trauma@ortho.hku.hk.

Zitieren

APA

Cheng, S. S. M., Yung, C. S., Wong, S. H., Yip, C. C. H., Khoo, I. J. R., Wong, T. W. K., & Fang, C. (2024). Computer modeling and validation testing for glenoid component rotation and optimal glenoid screw angles for reverse shoulder arthroplasty in an Asian population. International Orthopaedics. https://doi.org/10.1007/s00264-024-06340-z

Vancouver

Cheng SSM, Yung CS, Wong SH, Yip CCH, Khoo IJR, Wong TWK, et al. Computer modeling and validation testing for glenoid component rotation and optimal glenoid screw angles for reverse shoulder arthroplasty in an Asian population. International Orthopaedics. 2024. doi:10.1007/s00264-024-06340-z

BibTeX
@article{Cheng2024,
  author = {Cheng, Shun Sing Martin and Yung, Colin Shing-Yat and Wong, Samuel De Hoi and Yip, Christopher Chun Hei and Khoo, Issac Jun Ren and Wong, Tsoi Wan Karen and Fang, Christian},
  title = {Computer modeling and validation testing for glenoid component rotation and optimal glenoid screw angles for reverse shoulder arthroplasty in an Asian population},
  journal = {International Orthopaedics},
  year = {2024},
  doi = {10.1007/s00264-024-06340-z}
}
Kostenlos starten →