Kurz gefasst

Fachartikel in der Zeitschrift European Spine Journal, 2025. Verfasst von Kang Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Honghui Hospital, Xi'an Jiaotong University, Xi'an, China. Hauptthemen laut MEDLINE: Spinal Neoplasms, Vertebroplasty, Anesthesia, Local, Robotic Surgical Procedures. Die Arbeit nennt 30 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Research and Development Project of Shaanxi Province China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the clinical efficacy and safety of robot-assisted targeted co-ablation (CA) combined with percutaneous vertebroplasty (PVP) under local anesthesia for spinal metastases. METHODS: This was a retrospective study of 43 patients with spinal metastases treated in our hospital from October 2022 to October 2023. Among the 43 patients, 18 underwent robot-assisted targeted CA combined with PVP (CA group) and 25 underwent PVP alone (PVP group). The visual analogue scale (VAS), the Oswestry Disability Index (ODI), and the Karnofsky Performance Status (KPS) were used to evaluate the intensity of pain, and the quality of life. RESULTS: There were no significant differences in the baseline data between the two groups (P > 0.05). The time of puncture channel establishment in the CA group was significantly shorter than that in the PVP group (11.33 ± 2.22 vs. 26.72 ± 4.20 min, P 0.05). However, at the 6 months follow-up, patients of the CA group had significantly lower VAS and ODI scores than the PVP group, and the KPS was higher (P < 0.05). The imaging examination performed at 6 months after the operation revealed that only one patient (5.6%) in CA group experienced local tumor progression (LTP), whereas 9 patients (36%) in PVP group, and the difference was significant (P = 0.03). The incidence of cement leakage in CA group (11.1%) was significantly lower than that in PVP group (44%) (P = 0.02). Multivariate logistic regression analysis of independent risk factors against LTP confirmed that a maximum diameter of spinal metastases ≥ 3.0 cm is an independent risk factor (OR: 7.413, P = 0.022). While, robot-assisted targeted CA combined with PVP is an independent protective factor (OR: 0.095, P = 0.045). For cement leakage, robot-assisted CA combined with PVP was also the independent protective factor (OR: 0.159, P = 0.031). CONCLUSIONS: Robot-assisted targeted CA combined with PVP under local anesthesia can provide durable pain relief and improve the quality of life of patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spinal NeoplasmsVertebroplastyAnesthesia, LocalRobotic Surgical ProceduresAblation TechniquesHumansFemaleMaleRetrospective StudiesMiddle AgedAgedTreatment OutcomeCombined Modality TherapyQuality of Life

Stichwörter der Autor:innen

Co-ablation systemPVPSpineThe Tinavi orthopedic robot systemTumor

Autor:innen und Institutionen

  • Honghui Hospital, Xi'an Jiaotong University, Xi'an, China.
  • Xi'an Medical University, Xi'an, China.
  • Honghui Hospital, Xi'an Jiaotong University, Xi'an, China. haodingjun@126.com.

Förderung

  • National Natural Science Foundation of China
  • Key Research and Development Project of Shaanxi Province China

Zitieren

APA

Zheng, K., Wang, W., Liu, Z., Shan, L., & Hao, D. (2025). Clinical efficacy and safety of robot-assisted targeted co-ablation combined with vertebroplasty under local anesthesia for spinal metastases. European Spine Journal. https://doi.org/10.1007/s00586-025-09326-6

Vancouver

Zheng K, Wang W, Liu Z, Shan L, Hao D. Clinical efficacy and safety of robot-assisted targeted co-ablation combined with vertebroplasty under local anesthesia for spinal metastases. European Spine Journal. 2025. doi:10.1007/s00586-025-09326-6

BibTeX
@article{Zheng2025,
  author = {Zheng, Kang and Wang, Wentao and Liu, Zhengpei and Shan, Lequn and Hao, Dingjun},
  title = {Clinical efficacy and safety of robot-assisted targeted co-ablation combined with vertebroplasty under local anesthesia for spinal metastases},
  journal = {European Spine Journal},
  year = {2025},
  doi = {10.1007/s00586-025-09326-6}
}
Kostenlos starten →