Novel Use of Fractal Analysis for Quantifying Polymethylmethacrylate Distribution Patterns in Osteoporotic and Malignant Vertebral Compression Fractures Following Vertebroplasty
Canadian Association of Radiologists Journal · 2024
DOI: 10.1177/08465371241256908 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Association of Radiologists Journal, 2024. Verfasst von Mehran Nasralla und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University of Toronto, Toronto, ON, Canada. Hauptthemen laut MEDLINE: Fractures, Compression, Fractals, Vertebroplasty, Polymethyl Methacrylate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Fractal analysis is a mathematical tool which allows the evaluation of complex microstructural features within materials that cannot be expressed in traditional geometric terms. The purpose of this study is to quantify the differences in polymethylmethacrylate intravertebral cement spatial distribution patterns following vertebroplasty using fractal analysis through the examination of osteoporotic and malignant compression fractures.
Methods
Frontal and lateral post-vertebroplasty radiographs were evaluated from 29 patients with osteoporotic and malignant compression fractures who underwent vertebroplasty. The individually treated vertebra were divided into osteoporotic (n = 35) and malignant groups (n = 41). Images underwent segmentation, thresholding, and binarization prior to fractal analysis. Fractal dimension and lacunarity values were derived from the region of interest in treated vertebrae using the “box-counting” and “gliding-box” techniques respectively using ImageJ. The mean values of both parameters were compared between the 2 groups.
Results
The mean fractal dimension was significantly higher in the malignant vertebral compression fracture group (1.53 ± 0.08) compared to the osteoporotic group (1.34 ± 0.17; P < .001). Similarly, mean lacunarity values were significantly higher in the malignant fracture group (0.50 ± 0.09) compared to the osteoporotic group (0.37 ± 0.10; P < .001).
Conclusions
Fractal dimension and lacunarity values of cement spatial distribution patterns obtained from the post-vertebroplasty radiographs can differentiate between benign osteoporotic and malignant vertebral compression fractures. This novel technique may be useful for evaluating cement spatial distribution patterns in spine augmentation procedures, although further research is warranted in this area.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Neuroradiology, Joint Department of Medical Imaging, Toronto Western Hospital, University of Toronto, Toronto, ON, Canada.
- Department of Radiology, University of California San Diego, La Jolla, CA, USA.
ORCID-Profile: Mehran Nasralla
Zitieren
APA
Nasralla, M., Islam, S., Vucevic, D., & Murphy, K. (2024). Novel Use of Fractal Analysis for Quantifying Polymethylmethacrylate Distribution Patterns in Osteoporotic and Malignant Vertebral Compression Fractures Following Vertebroplasty. Canadian Association of Radiologists Journal. https://doi.org/10.1177/08465371241256908
Vancouver
Nasralla M, Islam S, Vucevic D, Murphy K. Novel Use of Fractal Analysis for Quantifying Polymethylmethacrylate Distribution Patterns in Osteoporotic and Malignant Vertebral Compression Fractures Following Vertebroplasty. Canadian Association of Radiologists Journal. 2024. doi:10.1177/08465371241256908
BibTeX
@article{Nasralla2024,
author = {Nasralla, Mehran and Islam, Shahriar and Vucevic, Diana and Murphy, Kieran},
title = {Novel Use of Fractal Analysis for Quantifying Polymethylmethacrylate Distribution Patterns in Osteoporotic and Malignant Vertebral Compression Fractures Following Vertebroplasty},
journal = {Canadian Association of Radiologists Journal},
year = {2024},
doi = {10.1177/08465371241256908}
}