EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Perfecting the pour: A novel co-axial technique with sequential injections for optimising cement delivery during sacroplasty

Mehran Nasralla iD, Afra Alfalahi iD, Eef J Hendriks iD, Kieran Murphy, Roger Smith

Interventional Neuroradiology · 2026

DOI: 10.1177/15910199241282709 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Interventional Neuroradiology, 2026. Verfasst von Mehran Nasralla und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neuroradiology, Joint Department of Medical imaging, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Sacrum, Bone Cements, Spinal Neoplasms, Spinal Fractures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Percutaneous sacroplasty is an effective treatment for painful sacral fractures and tumours, however there is no accepted optimal technique for performing this procedure. This study investigated a novel approach to sacroplasty combining co-axial sacral access, sequential cement injections and hypothermic cement manipulation to improve cement delivery.

Methods

This retrospective study analysed 11 patients who underwent co-axial sacroplasty between April 2023 and March 2024 for treatment of painful insufficiency fractures ( n = 5) or malignant sacral tumours ( n = 6). All cases were performed using biplane fluoroscopy with conebeam CT navigation for planning and monitoring percutaneous access. Procedural details, technical outcomes, and clinical outcomes including Numerical Rating Scale (NRS) pain and analgesic utilisation on a six-point scale were analysed pre-procedure and at follow-up.

Results

Technical success of was achieved in all cases using this technique. The mean injected cement volume was 20.5 ± 6.4 ml. Median pre-procedural NRS pain scores of 8 (IQR 7.25–8) significantly decreased to 0 (IQR, 0–0.25) at follow-up ( p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SacrumBone CementsSpinal NeoplasmsSpinal FracturesVertebroplastyFractures, StressHumansFemaleRetrospective StudiesMaleMiddle AgedAgedFluoroscopyTreatment OutcomeCone-Beam Computed TomographyRadiography, InterventionalAdult

Stichwörter der Autor:innen

Percutaneous sacroplastycement leakageco-axial sacroplastysacral insufficiency fracturessequential injection

Substanzen

Bone Cements

Autor:innen und Institutionen

  • Division of Neuroradiology, Joint Department of Medical imaging, Toronto Western Hospital, University of Toronto, Toronto, Ontario, Canada.

ORCID-Profile: Mehran Nasralla, Afra Alfalahi, Eef J Hendriks

Zitieren

APA

Nasralla, M., Alfalahi, A., Hendriks, E. J., Murphy, K., & Smith, R. (2026). Perfecting the pour: A novel co-axial technique with sequential injections for optimising cement delivery during sacroplasty. Interventional Neuroradiology. https://doi.org/10.1177/15910199241282709

Vancouver

Nasralla M, Alfalahi A, Hendriks EJ, Murphy K, Smith R. Perfecting the pour: A novel co-axial technique with sequential injections for optimising cement delivery during sacroplasty. Interventional Neuroradiology. 2026. doi:10.1177/15910199241282709

BibTeX
@article{Nasralla2026,
  author = {Nasralla, Mehran and Alfalahi, Afra and Hendriks, Eef J and Murphy, Kieran and Smith, Roger},
  title = {Perfecting the pour: A novel co-axial technique with sequential injections for optimising cement delivery during sacroplasty},
  journal = {Interventional Neuroradiology},
  year = {2026},
  doi = {10.1177/15910199241282709}
}
Kostenlos starten →