EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Image quality and procedural safety in neonatal brain MRI with and without sedation

Julia Greiser, Laurens Winkelmeier, Jochen Herrmann, Fabian Flottmann, Chinedu Ulrich Ebenebe

European Journal of Pediatrics · 18.11.2026 · 185 (12)

DOI: 10.1007/s00431-026-07656-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Pediatrics, online erschienen am 18.11.2026. Verfasst von Julia Greiser und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Neonatology and Pediatric Intensive Care, Department of Pediatrics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Procedural Sedation. Die Arbeit nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Hamburg-Eppendorf (UKE).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Neontal brain magnetic resonance imaging (MRI) is susceptible to motion artefacts, whereas pharmacological sedation or anaesthesia may cause cardiorespiratory adverse events. We compared image quality and adverse events across three MRI strategies in newborns: natural sleep without sedation, pharmacological sedation, and imaging during mechanical ventilation. We retrospectively analysed 151 brain MRI examinations performed in a tertiary neonatal intensive care unit between August 2013 and August 2024. Examinations were classified as non-sedated using a feed-and-swaddle approach ( n = 21), pharmacologically sedated without intubation ( n = 67), or performed in intubated and mechanically ventilated infants ( n = 63). Motion artefacts and documented adverse events were compared between groups. Motion artefacts were more frequent in non-sedated examinations than in sedated or intubated examinations (85.7% vs. 32.8% and 25.4%, respectively; p < 0.001). Moderate/severe artefacts occurred in 14.3%, 7.5%, and 0%, respectively. No adverse events were documented in the non-sedated group, compared with 8/67 (11.9%) in sedated and 7/63 (11.1%) in intubated infants; this difference was not statistically significant ( p = 0.275). Within the sedated cohort, artefacts were more frequent with chloral hydrate, whereas respiratory complications occurred predominantly with propofol-based sedation. Conclusion : Neonatal MRI strategies involve a clinically relevant trade-off between image quality and procedural safety. Natural-sleep MRI avoids pharmacological exposure and was not associated with documented adverse events but resulted in more motion artefacts. MRI strategies should therefore be individualized according to clinical condition and required diagnostic image quality. What is Known :• Motion artefacts may compromise neonatal MRI, and pharmacological sedation or anaesthesia is frequently used to improve image quality .• Feed-and-swaddle MRI can avoid drug exposure, while sedative and anaesthetic agents may cause respiratory and haemodynamic adverse events . What is New :• Direct comparison of three real-world neonatal MRI strategies demonstrates a trade-off between image quality and procedural safety: sedation and controlled ventilation reduced motion artefacts, whereas no adverse events were documented during natural-sleep MRI .• Exploratory analyses suggest differences between sedation regimens, with more artefacts after chloral hydrate and respiratory events occurring predominantly with propofol-based sedation .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainProcedural SedationHumansInfant, NewbornRetrospective StudiesArtifactsFemaleMaleHypnotics and SedativesIntensive Care Units, NeonatalRespiration, Artificial

Stichwörter der Autor:innen

AnaesthesiaFeed-and-swaddleMotion artefactsNeonatal MRIPatient safetySedation

Substanzen

Hypnotics and Sedatives

Autor:innen und Institutionen

  • Division of Neonatology and Pediatric Intensive Care, Department of Pediatrics, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany. j.greiser@uke.de.
  • Department of Diagnostic and Interventional Neuroradiology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Section of Pediatric Radiology, Department of Interventional and Diagnostic Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Department of Pediatrics, St. Marienkrankenhaus, Salzburger Strasse 15, 67067, Ludwigshafen, Germany.

Förderung

  • Universitätsklinikum Hamburg-Eppendorf (UKE)

Zitieren

APA

Greiser, J., Winkelmeier, L., Herrmann, J., Flottmann, F., & Ebenebe, C. U. (2026). Image quality and procedural safety in neonatal brain MRI with and without sedation. European Journal of Pediatrics, 185(12). https://doi.org/10.1007/s00431-026-07656-1

Vancouver

Greiser J, Winkelmeier L, Herrmann J, Flottmann F, Ebenebe CU. Image quality and procedural safety in neonatal brain MRI with and without sedation. European Journal of Pediatrics. 2026;185(12). doi:10.1007/s00431-026-07656-1

BibTeX
@article{Greiser2026,
  author = {Greiser, Julia and Winkelmeier, Laurens and Herrmann, Jochen and Flottmann, Fabian and Ebenebe, Chinedu Ulrich},
  title = {Image quality and procedural safety in neonatal brain MRI with and without sedation},
  journal = {European Journal of Pediatrics},
  year = {2026},
  volume = {185},
  number = {12},
  doi = {10.1007/s00431-026-07656-1}
}
Kostenlos starten →