EUVIMEDEUVIMED entdecken
Crossref

Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study

Su Young Yun, Young Jin Heo iD

Acta Radiologica · 2024

DOI: 10.1177/02841851241245104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2024. Verfasst von Su Young Yun und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea. Hauptthemen laut MEDLINE: Brain Neoplasms, Feasibility Studies, Magnetic Resonance Imaging, Imaging, Three-Dimensional. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time.

Purpose

To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients. Material and Methods For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratio lesion/parenchyma , and number of enhancing lesions for standard and accelerated T1-SPACE without ID.

Results

Although there was a significant difference in the overall image quality and mean contrast-to-noise ratio lesion/parenchyma between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size.

Conclusion

Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain NeoplasmsFeasibility StudiesMagnetic Resonance ImagingImaging, Three-DimensionalArtifactsContrast MediaHumansFemaleRetrospective StudiesMaleMiddle AgedAgedAdultBrainSignal-To-Noise RatioAged, 80 and overImage Enhancement

Stichwörter der Autor:innen

Iterative denoisingSPACESampling Perfection with Application-optimized Contrasts using different flip a…acceleratedbrainmetastases

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Inje University Busan Paik Hospital, Busan, Republic of Korea.

ORCID-Profile: Young Jin Heo

Zitieren

APA

Yun, S. Y., & Heo, Y. J. (2024). Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study. Acta Radiologica. https://doi.org/10.1177/02841851241245104

Vancouver

Yun SY, Heo YJ. Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study. Acta Radiologica. 2024. doi:10.1177/02841851241245104

BibTeX
@article{Yun2024,
  author = {Yun, Su Young and Heo, Young Jin},
  title = {Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study},
  journal = {Acta Radiologica},
  year = {2024},
  doi = {10.1177/02841851241245104}
}