EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

Critical flicker fusion frequency: confounders and caveats

Thomas Muth, Jochen D Schipke, Anne-Kathrin Brebeck, Sven Dreyer

European Journal of Applied Physiology · 2026

DOI: 10.1007/s00421-025-05935-7 ↗

At a glance

Journal article in European Journal of Applied Physiology, 2026. Written by Thomas Muth and 3 co-authors. Institution: Faculty of Medicine, Institute of Occupational, Social, Environmental Medicine, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany. Major MEDLINE topics: Flicker Fusion, Diving, Visual Perception. Cited 4 times so far (Crossref); 69 references. The full text is freely available (open access, CC BY 4.0). Funded by: Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts.

RezumatSubjectsDate bibliograficeCiteRelated studies

Abstract (original language)

Introduction

Critical flicker fusion frequency (cFFF) measures visual perception, with higher values indicating better performance. It is widely used to assess the effects of breathing gases in diving and hyperbaric environments.

Aim

Identify confounders explaining inconsistent cFFF study results.

Methods

Four experiments using a manual flicker device in volunteers with healthy eyes: 1. cFFF was measured in 174 recreational divers to examine demographic effects. 2. One male diver was tested daily over 85 days. 3. In 28 divers, cFFF was measured before and after 5 min of normobaric oxygen. 4. In 24 divers, cFFF was tested with and without diving masks, plus a condition with diagonal flicker light on the mask.

Results

1. Mean cFFF: 39.2 ± 5.1 Hz; decreased with age ( p < 0.001), no gender/BMI effect. 2. Mean: 43.4 ± 2.1 Hz; stable across lighting. 3. Thresholds differed by frequency order; minimal O₂ effect. 4. Masks had no effect, but diagonal light reduced cFFF ( p < 0.01). Conclusion cFFF varied by 13% across divers and 5% in a single diver. Age and observer-light geometry influenced results. Oxygen had minor impact. Findings support using age-specific norms and considering perceptual confounders in diving research.

Subjects

MeSH terms (MEDLINE)

Flicker FusionDivingVisual PerceptionHumansMaleAdultFemaleMiddle AgedYoung AdultOxygen

Author keywords

AgeCritical flicker fusion frequencyDiversLightingNitrogenOxygen

Substances

Oxygen

Authors and institutions

  • Faculty of Medicine, Institute of Occupational, Social, Environmental Medicine, Heinrich-Heine-University Düsseldorf, Düsseldorf, Germany.
  • Research Group Experimental Surgery, University Hospital Düsseldorf, Moorenstrasse 5, 40225, Düsseldorf, Germany. j.schipke@gmx.org.
  • Artemis MVZ Frankfurt, Main, Frankfurt, Germany.
  • Hyperbaric Oxygen Therapy, University Hospital Düsseldorf, Düsseldorf, Germany.

Funding

  • Universitätsklinikum Düsseldorf. Anstalt öffentlichen Rechts

Cite

APA

Muth, T., Schipke, J. D., Brebeck, A. K., & Dreyer, S. (2026). Critical flicker fusion frequency: confounders and caveats. European Journal of Applied Physiology. https://doi.org/10.1007/s00421-025-05935-7

Vancouver

Muth T, Schipke JD, Brebeck AK, Dreyer S. Critical flicker fusion frequency: confounders and caveats. European Journal of Applied Physiology. 2026. doi:10.1007/s00421-025-05935-7

BibTeX
@article{Muth2026,
  author = {Muth, Thomas and Schipke, Jochen D and Brebeck, Anne-Kathrin and Dreyer, Sven},
  title = {Critical flicker fusion frequency: confounders and caveats},
  journal = {European Journal of Applied Physiology},
  year = {2026},
  doi = {10.1007/s00421-025-05935-7}
}