Assessing Critical Flicker Fusion Frequency: Which Confounders? A Narrative Review
Medicina · 2023
DOI: 10.3390/medicina59040800 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Medicina, 2023. Verfasst von Thomas Muth und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Occupational, Social, Environmental Medicine, Faculty of Medicine, Heinrich-Heine-University Düsseldorf, 40225 Düsseldorf, Germany. Hauptthemen laut MEDLINE: Flicker Fusion, Diving. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 107 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The critical flicker fusion frequency (cFFF) refers to the frequency at which a regularly recurring change of light stimuli is perceived as steady. The cFFF threshold is often assessed in clinics to evaluate the temporal characteristics of the visual system, making it a common test for eye diseases. Additionally, it serves as a helpful diagnostic tool for various neurological and internal diseases. In the field of diving/hyperbaric medicine, cFFF has been utilized to determine alertness and cognitive functions. Changes in the cFFF threshold have been linked to the influence of increased respiratory gas partial pressures, although there exist inconsistent results regarding this effect. Moreover, the use of flicker devices has produced mixed outcomes in previous studies. This narrative review aims to explore confounding factors that may affect the accuracy of cFFF threshold measurements, particularly in open-field studies. We identify five broad categories of such factors, including (1) participant characteristics, (2) optical factors, (3) smoking/drug use, (4) environmental aspects, and (5) breathing gases and partial pressures. We also discuss the application of cFFF measurements in the field of diving and hyperbaric medicine. In addition, we provide recommendations for interpreting changes in the cFFF threshold and how they are reported in research studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Occupational, Social, Environmental Medicine, Faculty of Medicine, Heinrich-Heine-University Düsseldorf, 40225 Düsseldorf, Germany.
- Research Group Experimental Surgery, University Hospital Düsseldorf, 40225 Düsseldorf, Germany.
- Artemis Augenklinik, 60314 Frankfurt, Germany.
- Hyperbaric Oxygen Therapy, University Hospital Düsseldorf, 40225 Düsseldorf, Germany.
ORCID-Profile: Jochen D Schipke, Anne-Kathrin Brebeck
Zitieren
APA
Muth, T., Schipke, J. D., Brebeck, A. K., & Dreyer, S. (2023). Assessing Critical Flicker Fusion Frequency: Which Confounders? A Narrative Review. Medicina. https://doi.org/10.3390/medicina59040800
Vancouver
Muth T, Schipke JD, Brebeck AK, Dreyer S. Assessing Critical Flicker Fusion Frequency: Which Confounders? A Narrative Review. Medicina. 2023. doi:10.3390/medicina59040800
BibTeX
@article{Muth2023,
author = {Muth, Thomas and Schipke, Jochen D and Brebeck, Anne-Kathrin and Dreyer, Sven},
title = {Assessing Critical Flicker Fusion Frequency: Which Confounders? A Narrative Review},
journal = {Medicina},
year = {2023},
doi = {10.3390/medicina59040800}
}
EUVIMED