Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses
Graefe's Archive for Clinical and Experimental Ophthalmology · 2024
DOI: 10.1007/s00417-024-06528-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Xiaoling Fang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/ Shanghai Eye Hospital, School of Medicine, Tongji University, Nation…. Hauptthemen laut MEDLINE: Pupil, Visual Acuity, Lenses, Intraocular, Depth Perception. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Natural Science Foundation of Shanghai Municipality.
Abstract (Originalsprache)
PURPOSE: To evaluate whether depth of focus after the implantation of extended depth of focus (EDoF) intraocular lenses (IOLs) correlates with pupillary size. METHODS: This retrospective case series study evaluated eyes undergoing cataract surgery with implantation of EDoF IOLs. At least one month postoperatively, the depth of focus (DoF) was measured to determine the correlation with pupillary size, age, anterior chamber depth (ACD), axial length (AXL), and corneal spherical aberrations (SA). RESULTS: The study evaluated 64 eyes of 49 patients. The mean depth of focus was 2.67 diopters (D). The mean preoperative photopic pupil size was 3.36 mm. A significant negative association was found between preoperative photopic pupil size and depth of focus (r = 0.30, Pearson's correlation coefficient) and between preoperative mesopic pupil size and depth of focus (r = 0.274, Pearson's correlation coefficient).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Shanghai Eye Diseases Prevention &Treatment Center/ Shanghai Eye Hospital, School of Medicine, Tongji University, National Clinical Research Center for Eye Diseases,Shanghai Engineering Rese…
Förderung
- Natural Science Foundation of Shanghai Municipality
Zitieren
APA
Fang, X., Xue, W., Yu, C., Tao, J., & Wang, Y. (2024). Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06528-4
Vancouver
Fang X, Xue W, Yu C, Tao J, Wang Y. Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06528-4
BibTeX
@article{Fang2024,
author = {Fang, Xiaoling and Xue, Wenwen and Yu, Chunxia and Tao, Jinhua and Wang, Yulan},
title = {Correlation between pupillary size and depth of focus after the implantation of extended depth of focus intraocular lenses},
journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
year = {2024},
doi = {10.1007/s00417-024-06528-4}
}
EUVIMED