EUVIMEDEUVIMED entdecken
Crossref

Experimental evaluation of backscatter factors in paediatric head radiography using a novel in-house heterogeneous tissue-equivalent Phantom

Hamza Sekkat, Abdellah Khallouqi, Abdellah Halimi, Omar El Rhazouani

Radiation and Environmental Biophysics · 2026

DOI: 10.1007/s00411-025-01191-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation and Environmental Biophysics, 2026. Verfasst von Hamza Sekkat und 3 weiteren Autor:innen. Beteiligte Einrichtung: Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, 2600…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Scattering, Radiation, Head, Radiography. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paediatric patients are particularly sensitive to ionizing radiation, and accurate surface dose estimation is crucial in diagnostic X-ray imaging. Standard homogeneous phantoms inadequately reproduce tissue heterogeneity, leading to errors in backscatter evaluation. This study aimed to characterize backscatter factors (BSFs) in a heterogeneous, tissue-equivalent paediatric head phantom under conventional radiography conditions. An in-house epoxy-based heterogeneous phantom was fabricated with five inserts simulating bone, brain, cerebrospinal fluid, eye lens and air cavities. Entrance surface dose (ESD) and BSF measurements were performed using an ionization chamber and a Fujifilm digital X-ray system (40-150 kVp, field sizes: 10 × 10, 20 × 20, 25 × 25 cm²). Additional aluminium filtrations of 2.5 mm and 3.0 mm were applied to evaluate beam hardening effects. Measured ESD increased from 0.82 mGy at 40 kVp to 18.93 mGy at 150 kVp (no filtration, 25 × 25 cm²). Applying 3.0 mm Al filtration reduced ESD by up to 57% at 60 kVp. Experimental BSFs ranged from 1.1 to 2.1, increasing with tube potential and reaching a maximum under small field size and hardened beam (120 kVp, 10 × 10 cm², 3.0 mm Al), reflecting enhanced cumulative backscatter energy from heterogeneous tissue interfaces. Compared with IAEA TRS-457 reference data, the heterogeneous phantom yielded higher BSFs than PMMA or water for 10 × 10 cm² fields, demonstrating enhanced scatter from realistic tissue interfaces, while lower BSFs were observed for larger fields. The study confirms that homogeneous phantoms may underestimate paediatric backscatter under specific conditions, while heterogeneous phantoms provide more representative dosimetric references, improving BSF estimation and dose optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingScattering, RadiationHeadRadiographyHumansChildRadiation Dosage

Stichwörter der Autor:innen

Backscatter factorBeam filtrationEffective energyEntrance surface doseHeterogeneous phantomPaediatric radiology

Autor:innen und Institutionen

  • Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, 26000, Morocco. sekkat.isss@uhp.ac.ma.
  • Sciences and Engineering of Biomedicals, Biophysics and Health Laboratory, Higher Institute of Health Sciences, Hassan First University, Settat, 26000, Morocco.
  • Department of Radiology, Public Hospital of Mediouna, Mediouna, Morocco.
  • Department of Radiology, Private Hospital of Hay Mouhamadi, Casablanca, Morocco.

Zitieren

APA

Sekkat, H., Khallouqi, A., Halimi, A., & Rhazouani, O. E. (2026). Experimental evaluation of backscatter factors in paediatric head radiography using a novel in-house heterogeneous tissue-equivalent Phantom. Radiation and Environmental Biophysics. https://doi.org/10.1007/s00411-025-01191-7

Vancouver

Sekkat H, Khallouqi A, Halimi A, Rhazouani OE. Experimental evaluation of backscatter factors in paediatric head radiography using a novel in-house heterogeneous tissue-equivalent Phantom. Radiation and Environmental Biophysics. 2026. doi:10.1007/s00411-025-01191-7

BibTeX
@article{Sekkat2026,
  author = {Sekkat, Hamza and Khallouqi, Abdellah and Halimi, Abdellah and Rhazouani, Omar El},
  title = {Experimental evaluation of backscatter factors in paediatric head radiography using a novel in-house heterogeneous tissue-equivalent Phantom},
  journal = {Radiation and Environmental Biophysics},
  year = {2026},
  doi = {10.1007/s00411-025-01191-7}
}
Kostenlos starten →