Vergleichsstudie in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Jérôme Murgier und 2 weiteren Autor:innen. Beteiligte Einrichtung: Aguilera Clinique, Ramsay Santé, France. murgier.jerome@hotmail.fr. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Prosthesis Design, Noise. Die Arbeit nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: After total knee arthroplasty (TKA), patients may experience noise generated by their replaced knee. This study aimed to assess the impact of prosthesis design on noise generation. METHOD: This single centre comparative retrospective study was conducted including 200 patients who underwent a TKA between 2020 and 2022 with a minimum of 2 years of follow-up. The SKV, IKS, satisfaction score and Kuriyama questionnaires were completed. Three prosthesis designs were assessed: Medial Pivot (MP) - Microport®, Mobile Bearing (MB) - Amplitude® and Cruciate Retaining (CR) - Stryker®. RESULTS: The MP design generated less noise than the MB or CR design. In the MP group, 74.5% of patients did not describe any noise compared to 61.4% for the MB group and 62.1% for the CR group. The rate of patients experiencing noise from their prosthesis was 32%. The majority of patients were very satisfied (68%) or satisfied (24%) with their surgery. Patients who had a silent prosthesis were more satisfied than those who had a prosthesis that generated noise, with a greater proportion of patients in the satisfied/very satisfied group (93% versus 84%); p = 0.02. The average SKV score was 81.8 (± 4.7) in the silent group versus 75 (± 4.6) in the noise group (NS). The functional difference (IKS function score) between the two groups was not statistically significant (36 (± 2.5); 34.6 (± 3.4) vs. p = 0.12). CONCLUSION: The MP design generates less noise than MB and CR at two years of follow-up after a TKA. LEVEL OF EVIDENCE III: Retrospective comparative study.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis DesignNoiseHumansRetrospective StudiesMaleFemaleAgedPatient SatisfactionMiddle AgedAged, 80 and over

Stichwörter der Autor:innen

FunctionNoisePatient reported outcomesTotal knee arthroplastyTotal knee replacement

Autor:innen und Institutionen

  • Aguilera Clinique, Ramsay Santé, France. murgier.jerome@hotmail.fr.
  • Orthopedic Department, Purpan Hospital, Toulouse, France.

Zitieren

APA

Murgier, J., Tourcher, T., & Cavaignac, E. (2025). Medial Pivot prostheses generate less noise than mobile bearing and cruciate retaining total knee arthroplasties. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-05906-9

Vancouver

Murgier J, Tourcher T, Cavaignac E. Medial Pivot prostheses generate less noise than mobile bearing and cruciate retaining total knee arthroplasties. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-05906-9

BibTeX
@article{Murgier2025,
  author = {Murgier, Jérôme and Tourcher, Thibaut and Cavaignac, Etienne},
  title = {Medial Pivot prostheses generate less noise than mobile bearing and cruciate retaining total knee arthroplasties},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2025},
  doi = {10.1007/s00402-025-05906-9}
}
Kostenlos starten →