EUVIMEDEUVIMED entdecken
Crossref

Aseptic revision from one rotating-hinge to another rotating-hinge prosthesis – how good are the results?

Benedikt Paul Blersch, Florian Hubert Sax, Bernd Fink

Archives of Orthopaedic and Trauma Surgery · 2025

DOI: 10.1007/s00402-025-06133-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2025. Verfasst von Benedikt Paul Blersch und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany. bblersch@bgu-tue…. Hauptthemen laut MEDLINE: Reoperation, Prosthesis Failure, Knee Prosthesis, Arthroplasty, Replacement, Knee. Die Arbeit nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Evidence on the outcome of aseptic exchange of rotating-hinge prosthesis is missing in the literature. This study aimed to evaluate implant survival, complication rates, and clinical outcomes following revision of a rotating-hinge prosthesis to another rotating-hinge prosthesis with anatomical axis. MATERIALS AND METHODS: Between March 2014 and Juli 2023 62 cases of aseptic exchange of a rotating-hinge prosthesis were performed at a tertiary medical center in Germany. In this retrospective study, all patients were contacted for clinical follow-up and prosthesis survival. Implant survival was analyzed using the Kaplan-Meier method, and clinical outcomes were assessed using the Knee Society Score. RESULTS: The 5-year implant survival rate was 83.4% (73.2-93.6, 95%-CI) for revision due to any reason, 85.1% (75.3-94.9, 95%-CI) for aseptic failure and 98.0% (94.1-100.0, 95%-CI: ) for septic failure. The estimated 10-year survival rates were 73.2% (59.2-87.1%; 95%-CI), 78.0% (65.1-90.9%; 95%-CI), and 93.9% (85.3-100.0%; 95%-CI), respectively. Improvements were observed in all KSS subdomains except for the Patient Expectation Score. CONCLUSIONS: The exchange of a rotating-hinge prosthesis, using metaphyseal cones when indicated for bone defects, yields implant survival and complication rates comparable to those of primary rotating-hinge prosthesis implantation. However, clinical outcome scores tend to be lower than those reported for first-time implantation of rotating-hinge prostheses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ReoperationProsthesis FailureKnee ProsthesisArthroplasty, Replacement, KneeHumansRetrospective StudiesMaleFemaleMiddle AgedAgedProsthesis DesignAdultAged, 80 and over

Stichwörter der Autor:innen

Aseptic knee revisionAxis-guided knee prosthesisConesRevision knee arthroplastyRotating-hinge knee prosthesis

Autor:innen und Institutionen

  • Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany. bblersch@bgu-tuebingen.de.
  • Department of Trauma and Reconstructive Surgery, BG Klinik, University of Tübingen, Tübingen, Germany. bblersch@bgu-tuebingen.de.
  • Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany.
  • Department of Joint Replacement, General and Rheumatic Orthopaedics, Orthopaedic Clinic Markgröningen gGmbH, Markgröningen, Germany. bernd.fink@rkh-gesundheit.de.
  • Orthopaedic Department, University Hospital Hamburg-Eppendorf, Hamburg, Germany. bernd.fink@rkh-gesundheit.de.

Zitieren

APA

Blersch, B. P., Sax, F. H., & Fink, B. (2025). Aseptic revision from one rotating-hinge to another rotating-hinge prosthesis – how good are the results?. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-025-06133-y

Vancouver

Blersch BP, Sax FH, Fink B. Aseptic revision from one rotating-hinge to another rotating-hinge prosthesis – how good are the results?. Archives of Orthopaedic and Trauma Surgery. 2025. doi:10.1007/s00402-025-06133-y

BibTeX
@article{Blersch2025,
  author = {Blersch, Benedikt Paul and Sax, Florian Hubert and Fink, Bernd},
  title = {Aseptic revision from one rotating-hinge to another rotating-hinge prosthesis – how good are the results?},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2025},
  doi = {10.1007/s00402-025-06133-y}
}