Spacer rotation technique allows precise evaluation of gap balance in total knee arthroplasty
Archives of Orthopaedic and Trauma Surgery · 2024
DOI: 10.1007/s00402-024-05253-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2024. Verfasst von Georg Matziolis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. g.matziolis@waldkliniken-…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Cadaver. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Jena.
Abstract (Originalsprache)
The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany. g.matziolis@waldkliniken-eisenberg.de.
- Orthopaedic Department, University Hospital Jena, Campus Eisenberg, Klosterlausnitzer Straße 81, 07607, Eisenberg, Germany.
- Center for Orthopaedics, Trauma Surgery and Rehabilitation Medicine, University Medicine Greifswald, 17475, Greifswald, Germany.
Förderung
- Universitätsklinikum Jena
Zitieren
APA
Matziolis, G., Layher, F., Vogt, S., Bergner, L., Wassilew, G., & Kirschberg, J. (2024). Spacer rotation technique allows precise evaluation of gap balance in total knee arthroplasty. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-024-05253-1
Vancouver
Matziolis G, Layher F, Vogt S, Bergner L, Wassilew G, Kirschberg J. Spacer rotation technique allows precise evaluation of gap balance in total knee arthroplasty. Archives of Orthopaedic and Trauma Surgery. 2024. doi:10.1007/s00402-024-05253-1
BibTeX
@article{Matziolis2024,
author = {Matziolis, Georg and Layher, Frank and Vogt, Sophia and Bergner, Leah and Wassilew, Georgi and Kirschberg, Julia},
title = {Spacer rotation technique allows precise evaluation of gap balance in total knee arthroplasty},
journal = {Archives of Orthopaedic and Trauma Surgery},
year = {2024},
doi = {10.1007/s00402-024-05253-1}
}
EUVIMED