EUVIMEDEUVIMED entdecken
Crossref

No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up

Ji-Hoon Baek, Su Chan Lee, Suengryol Ryu, Hye Sun Ahn, Chang Hyun Nam

Archives of Orthopaedic and Trauma Surgery · 2023

DOI: 10.1007/s00402-023-04789-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Orthopaedic and Trauma Surgery, 2023. Verfasst von Ji-Hoon Baek und 4 weiteren Autor:innen. Beteiligte Einrichtung: Joint and Arthritis Research, Department of Orthopaedic Surgery, Himchan Hospital, 120, Sinmok-Ro, Yangcheon-Gu, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Tibial Fractures. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to assess tibial post fracture between highly cross-linked polyethylene (HXPE) and conventional polyethylene inserts in consecutive posterior-stabilized (PS) total knee arthroplasty (TKA) over a minimum 10-years follow-up period. METHODS: Between July 2008 and December 2011, a consecutive series of 3264 primary TKAs was performed in 2098 patients using a PS total knee prosthesis at a single institution. The final cohort was classified into the HXPE group (792 cases) and the conventional group (2113 cases) according to insert material used during the procedure. RESULTS: The mean follow-up period was 11.4 years in the HXPE group and 11.8 years in the conventional group. Both cases of tibial post fracture occurred in the HXPE group, a complication rate of 0.25%. These two cases required replacement with a thicker tibial insert with retention of the femoral and tibial components. There were no cases of tibial post fracture in the conventional group. CONCLUSION: There was no difference in tibial post fracture rate between the HXPE group and the conventional group in PS TKA on long-term follow-up. LEVEL OF EVIDENCE: IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeKnee ProsthesisTibial FracturesHumansPolyethyleneKnee JointFollow-Up StudiesProsthesis DesignProsthesis Failure

Stichwörter der Autor:innen

Highly cross-linked polyethylenePosterior-stabilizedTibial post fractureTotal knee arthroplasty

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Joint and Arthritis Research, Department of Orthopaedic Surgery, Himchan Hospital, 120, Sinmok-Ro, Yangcheon-Gu, Seoul, Republic of Korea.
  • Department of Orthopaedic Surgery, Himnaera Hospital, Busan, Republic of Korea.
  • Joint and Arthritis Research, Department of Orthopaedic Surgery, Himchan Hospital, 120, Sinmok-Ro, Yangcheon-Gu, Seoul, Republic of Korea. himchanhospital@gmail.com.

Zitieren

APA

Baek, J. H., Lee, S. C., Ryu, S., Ahn, H. S., & Nam, C. H. (2023). No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up. Archives of Orthopaedic and Trauma Surgery. https://doi.org/10.1007/s00402-023-04789-y

Vancouver

Baek JH, Lee SC, Ryu S, Ahn HS, Nam CH. No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up. Archives of Orthopaedic and Trauma Surgery. 2023. doi:10.1007/s00402-023-04789-y

BibTeX
@article{Baek2023,
  author = {Baek, Ji-Hoon and Lee, Su Chan and Ryu, Suengryol and Ahn, Hye Sun and Nam, Chang Hyun},
  title = {No higher tibial post fracture rate with highly cross-linked polyethylene inserts in total knee arthroplasty at a minimum 10-year follow-up},
  journal = {Archives of Orthopaedic and Trauma Surgery},
  year = {2023},
  doi = {10.1007/s00402-023-04789-y}
}
Kostenlos starten →