The influence of implant design and limb alignment on in vivo wear rates of fixed‐bearing and rotating‐platform knee implant retrievals
Journal of Orthopaedic Research · 2024
DOI: 10.1002/jor.25734 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthopaedic Research, 2024. Verfasst von Michael J Dreyer und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland. Hauptthemen laut MEDLINE: Knee Prosthesis, Arthroplasty, Replacement, Knee. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Analysis of polyethylene (PE) wear in knee implants is crucial for understanding the factors leading to revision in total knee arthroplasty. Importantly, current experimental and computational methods for predicting insert wear can only be validated against true in vivo measurements from retrievals. This study quantitatively investigated in vivo PE wear rates in fixed‐bearing (FB) ( n = 21) and rotating‐platform ( n = 53) implant retrievals. 3D surface geometry of the retrievals was measured using a structured light scanner. Then, a reference surface that included the deformation, but not the wear that the retrievals had experienced in vivo, was constructed using a fully automatic surface reconstruction algorithm. Finally, wear volume was calculated from the deviation between the worn and reconstructed surfaces. The measurement and analysis techniques were validated and the algorithm was found to produce errors of only 0.2% relative to the component volumes. In addition to quantifying cohort‐level wear rates, the effect of mechanical axis limb alignment on mediolateral wear distribution was examined for a subset of the retrievals ( n = 14 + 26). Our results show that FB implants produce significantly ( p = 0.04) higher topside wear rates (24.6 ± 10.1 mm 3 /year) than rotating‐platform implants (15.3 ± 8.0 mm 3 /year). This effect was larger than that of limb alignment, which had a smaller and nonsignificant influence on overall wear rates (+4.5 ± 11.6 mm 3 /year, p = 0.43). However, increased varus alignment was associated significantly with greater medial compartment wear in both the FB and rotating‐platform designs (+1.7 ± 1.3%/° and +1.8 ± 1.6%/°). Our findings emphasize the importance of implant design and limb alignment on wear outcomes, providing reference data for improving implant performance and longevity.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory for Movement Biomechanics, Institute for Biomechanics, ETH Zürich, Zürich, Switzerland.
- Laboratory for Mechanical Systems Engineering, Empa, Dübendorf, Switzerland.
- Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Viña del Mar, Chile.
- Center for X-ray Analytics, Empa, Dübendorf, Switzerland.
- Department of Lower Extremities, Schulthess Clinic, Zürich, Switzerland.
ORCID-Profile: Michael J Dreyer, José Ignacio Contreras Raggio, William R Taylor
Zitieren
APA
Dreyer, M. J., Weisse, B., Contreras Raggio, J. I., Zboray, R., Taylor, W. R., Preiss, S., & Horn, N. (2024). The influence of implant design and limb alignment on in vivo wear rates of fixed‐bearing and rotating‐platform knee implant retrievals. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.25734
Vancouver
Dreyer MJ, Weisse B, Contreras Raggio JI, Zboray R, Taylor WR, Preiss S, et al. The influence of implant design and limb alignment on in vivo wear rates of fixed‐bearing and rotating‐platform knee implant retrievals. Journal of Orthopaedic Research. 2024. doi:10.1002/jor.25734
BibTeX
@article{Dreyer2024,
author = {Dreyer, Michael J and Weisse, Bernhard and Contreras Raggio, José Ignacio and Zboray, Robert and Taylor, William R and Preiss, Stefan and Horn, Nils},
title = {The influence of implant design and limb alignment on in vivo wear rates of fixed‐bearing and rotating‐platform knee implant retrievals},
journal = {Journal of Orthopaedic Research},
year = {2024},
doi = {10.1002/jor.25734}
}