Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up
Knee Surgery, Sports Traumatology, Arthroscopy · 2025
DOI: 10.1002/ksa.12753 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2025. Verfasst von Carl Christian Holkgaard Burvil und 7 weiteren Autor:innen. Beteiligte Einrichtung: AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Knee Prosthesis, Osteoarthritis, Knee. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Aarhus University, The Danish Rheumatism Association, Toyota-Fonden.
Abstract (Originalsprache)
Purpose
To assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High‐constraint inserts may increase forces on components and potentially affect implant migration and long‐term fixation.
Methods
A cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo‐radiograph taken supine on the first postoperative day (baseline) and again at 3‐, 12‐, and 24‐month follow‐up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM).
Results
At the 12‐month follow‐up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: −0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64–0.99) in the MC group and 0.85 mm (95% CI: 0.68–1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow‐up ( p > 0.09). At the 12‐month follow‐up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: −0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83–1.32) in the MC group and 1.26 mm (95% CI: 1.01–1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03–0.32) and 0.20 mm (95% CI: 0.01–0.39) more lateral migration at 3‐ and 12‐month follow‐up, respectively. At the 24‐month follow‐up, there was no statistically significant differences in migration for either translations, rotations or MTPM.
Conclusions
Both tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. Level of Evidence Level I.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus N, Denmark.
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
- Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus N, Denmark.
- University Clinic for Hand, Hip and Knee Surgery, Gødstrup Hospital, Gødstrup, Denmark.
ORCID-Profile: Carl Christian Holkgaard Burvil, Karina Nørgaard Linde, Maiken Stilling, Torben Bæk Hansen, Søren Rytter, Daan Koppens, Emil Toft Petersen
Förderung
- Aarhus University
- The Danish Rheumatism Association
- Toyota-Fonden
- Købmand Sven Hansen og Hustru Ina Hansens Fond
- Søster og Verner Lipperts Fond
Zitieren
APA
Burvil, C. C. H., Linde, K. N., Stilling, M., Hansen, T. B., Dalsgaard, J., Rytter, S., Koppens, D., & Petersen, E. T. (2025). Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1002/ksa.12753
Vancouver
Burvil CCH, Linde KN, Stilling M, Hansen TB, Dalsgaard J, Rytter S, et al. Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up. Knee Surgery, Sports Traumatology, Arthroscopy. 2025. doi:10.1002/ksa.12753
BibTeX
@article{Burvil2025,
author = {Burvil, Carl Christian Holkgaard and Linde, Karina Nørgaard and Stilling, Maiken and Hansen, Torben Bæk and Dalsgaard, Jesper and Rytter, Søren and Koppens, Daan and Petersen, Emil Toft},
title = {Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2025},
doi = {10.1002/ksa.12753}
}
EUVIMED