Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT
European Radiology · 07.11.2026
DOI: 10.1007/s00330-026-13006-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Radiology, online erschienen am 07.11.2026. Verfasst von Changfeng Ji und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. Die Arbeit nennt 37 Literaturangaben. Gefördert von: Research Project of Jiangsu Provincial Health Commission.
Abstract (Originalsprache)
OBJECTIVE: This study aimed to evaluate the diagnostic performance of photon-counting detector computed tomography (PCD-CT) for gastric cancer T staging compared with conventional energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: Fifty-three patients with preoperative PCD-CT and 54 patients with preoperative EID-CT were retrospectively enrolled. Two radiologists independently assessed the visibility and T stages using all available sequences, including virtual monoenergetic images (VMIs) from PCD-CT at 40, 50, 60, and 70 kiloelectron volt (keV) levels. The lesion detectability and diagnostic accuracy of the two CT systems were analyzed and compared. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of gastric cancer lesions were also measured. RESULTS: Five lesions in the PCD-CT group and 12 lesions in the EID-CT group could not be confidently identified. For visible lesions, the overall T staging accuracies were 85.4% (95% CI: 72.8-92.8%) for Reader 1 and 83.3% (95% CI: 70.4-91.3%) for Reader 2 on PCD-CT, compared with 73.8% (95% CI: 58.9-84.7%) for Reader 1 and 78.6% (95% CI: 64.1-88.3%) for Reader 2 on EID-CT. The interobserver agreement for both CT systems was excellent, with weighted kappa values of 0.807 (95% CI: 0.693-0.921) for PCD-CT and 0.832 (95% CI: 0.720-0.943) for EID-CT. Quantitative analysis showed significantly higher SNR and CNR on PCD-CT than EID-CT (both p < 0.05). CONCLUSION: PCD-CT demonstrated significantly higher quantitative image quality metrics (SNR and CNR) and numerically higher diagnostic performance than EID-CT in this exploratory retrospective comparison. The potential value of PCD-CT in gastric cancer T staging warrants further validation. KEY POINTS: Question The diagnostic performance and potential value of PCD-CT in gastric cancer T staging are still unclear. Findings PCD-CT showed significantly higher quantitative image quality metrics (SNR and CNR) and numerically higher diagnostic performance than EID-CT in this exploratory comparison. Clinical relevance PCD-CT may offer potential value in gastric cancer T staging.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
- Department of Pathology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China.
- CT Collaboration, Siemens Healthineers Digital Technology (Shanghai) Co. Ltd., Shanghai, China.
- Customer Service, Siemens Healthineers Digital Technology (Shanghai) Co. Ltd., Shanghai, China.
- Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. shihuabella@126.com.
- Department of Radiology, Nanjing Drum Tower Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, China. glyyly91@163.com.
Förderung
- Research Project of Jiangsu Provincial Health Commission
Zitieren
APA
Ji, C., Li, L., Li, Y., Zhou, Y., Yang, W., Sun, S., Nie, K., Zhao, X., Shi, H., Liu, Y., & Liu, S. (2026). Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT. European Radiology. https://doi.org/10.1007/s00330-026-13006-4
Vancouver
Ji C, Li L, Li Y, Zhou Y, Yang W, Sun S, et al. Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT. European Radiology. 2026. doi:10.1007/s00330-026-13006-4
BibTeX
@article{Ji2026,
author = {Ji, Changfeng and Li, Lin and Li, Yuqing and Zhou, Yiju and Yang, Wan and Sun, Shuangshuang and Nie, Kehui and Zhao, Xi and Shi, Hua and Liu, Yu and Liu, Song},
title = {Photon-counting detector CT for gastric cancer T staging: a comparative assessment with conventional energy integrating detector CT},
journal = {European Radiology},
year = {2026},
doi = {10.1007/s00330-026-13006-4}
}
EUVIMED