Vergleichsstudie in der Zeitschrift Abdominal Radiology, online erschienen am 27.01.2025. Verfasst von Andrea Esquivel und 15 weiteren Autor:innen. Beteiligte Einrichtung: Mayo Clinic, Rochester, MN, USA. Hauptthemen laut MEDLINE: Kidney Calculi, Tomography, X-Ray Computed. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.
Abstract (Originalsprache)
PURPOSE: To compare same-day photon-counting detector CT (PCD-CT) to conventional energy-integrating detector CT (EID-CT) for detection of small renal stones (≤ 3 mm). METHODS: Patients undergoing clinical dual-energy EID-CT for known or suspected stone disease underwent same-day research PCD-CT. Patients with greater than 10 stones and no visible stones under 3 mm were excluded. Three radiologists selected the optimal reconstruction configuration for each CT modality and created the reference standard for renal stone presence. Two other radiologists, blinded to imaging modality, independently reviewed anonymized images to detect renal stones, rating confidence in potential stones using a Likert scale (1 = Definitely present, 2 = Probably present, 3 = Questionably present, 4 = Not seen). Sensitivity and false positive detections for PCD and EID-CT were calculated. RESULTS: Twenty-one patients underwent clinical EID-CT followed by same-day PCD-CT, with the reference standard identifying 121 renal stones (mean size 2.8 ± 2.6 mm). 0.4-mm PCD-CT images were more likely to display a stone as definitely present compared to 1- or 2-mm EID-CT images (p < 0.0001). Overall sensitivity for detection of all stones was greater at PCD-CT (0.75 vs. 0.55, p < 0.05). Pooled sensitivity of stones ≤ 3 mm was also significantly higher at PCD-CT (0.67 vs. 0.41, p < 0.05), with false positive detections differing between readers and modalities (PCD-CT vs. EID-CT: R1-7 v. 5; R2 - 7 v. 1). CONCLUSION: Sensitivity for renal stones was significantly higher using high spatial resolution PCD-CT vs. EID-CT, especially for stones 3 mm or less in size, which may be important for at-risk patient populations. Prospective evaluation in larger patient populations that will benefit from detection of small stones is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mayo Clinic, Rochester, MN, USA.
- University of Washington, Seattle, WA, USA.
- Mayo Clinic, Rochester, MN, USA. Fletcher.Joel@mayo.edu.
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Esquivel, A., Potretzke, T., Ferrero, A., Inoue, A., Hoodeshenans, S., Mileto, A., Winfree, T., Yalon, M., Khandelwal, A., Rajendran, K., Thorne, J. E., Lee, Y. S., Potretzke, A., Leng, S., McCollough, C. H., & Fletcher, J. G. (2025). Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT. Abdominal Radiology, 50(8), 3572-3583. https://doi.org/10.1007/s00261-024-04781-z
Vancouver
Esquivel A, Potretzke T, Ferrero A, Inoue A, Hoodeshenans S, Mileto A, et al. Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT. Abdominal Radiology. 2025;50(8):3572-3583. doi:10.1007/s00261-024-04781-z
BibTeX
@article{Esquivel2025,
author = {Esquivel, Andrea and Potretzke, Theodora and Ferrero, Andrea and Inoue, Akitoshi and Hoodeshenans, Safa and Mileto, Achille and Winfree, Timothy and Yalon, Mariana and Khandelwal, Ashish and Rajendran, Kishore and Thorne, Jamison E and Lee, Yong S and Potretzke, Aaron and Leng, Shuai and McCollough, Cynthia H and Fletcher, Joel G},
title = {Improved display and detection of small renal stones using photon-counting detector CT compared to conventional energy-integrating detector CT},
journal = {Abdominal Radiology},
year = {2025},
volume = {50},
number = {8},
pages = {3572--3583},
doi = {10.1007/s00261-024-04781-z}
}
EUVIMED