Precision of Ablation Margin Assessment After Liver Microwave Ablation: A Head-to-Head Comparison of Visual and Software-Assisted Methods
CardioVascular and Interventional Radiology · 2026
DOI: 10.1007/s00270-026-04528-x ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift CardioVascular and Interventional Radiology, 2026. Verfasst von Coline Morisot und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University Hospital of Saint-Etienne, Saint-Priest-en-Jarez, France. Hauptthemen laut MEDLINE: Liver Neoplasms, Software, Tomography, X-Ray Computed, Microwaves. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: CHU Saint-Étienne.
Abstract (Originalsprache)
Purpose
Minimal ablative margins (MAM) are critical for local tumour control after microwave ablation, yet their assessment remains subjective. We evaluated whether software improves the precision of ablation margin assessment after liver MWA. Materials and Methods In this retrospective study, patients undergoing CT-guided liver MWA between January 2019 and January 2025 were included. Two radiologists (with 4 and 5 years of experience in abdominal imaging) assessed MAM in two steps: first by side-by-side visual comparison of pre- and post-ablation CT using anatomical landmarks, then with dedicated software providing semi-automatic 3D co-registration and margin quantification. Each method included two reading sessions per reader, six weeks apart. Precision was assessed using intraclass correlation coefficients (ICC), Cohen’s kappa (κ) for categorical classification (< 5, 5–10, > 10 mm), and Bland–Altman analysis.
Results
Sixty-seven patients with 87 liver tumours were included. Visual assessment showed poor reliability, with low intrareader agreement (ICC 0.10 and 0.33) and near-random interreader agreement (κ = − 0.10; ICC − 0.05), with limits of agreement approaching 17 mm. Software-assisted assessment improved reliability, with higher intrareader ICCs (0.54 and 0.83) and improved interreader agreement (κ = 0.38; ICC = 0.54). Interreader bias decreased from − 2.84 to + 0.91 mm, and limits of agreement narrowed to − 4.10 to + 5.92 mm ( p < 0.001). The median absolute interreader difference decreased from 3.0 to 1.0 mm ( p < 0.001).
Conclusion
Software-assisted assessment improves reliability of MAM evaluation compared with visual methods, but interreader agreement remains only fair-to-moderate; further validation is required before routine clinical adoption.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University Hospital of Saint-Etienne, Saint-Priest-en-Jarez, France.
- Department of Nuclear Medicine, University Hospital of Saint-Etienne, Saint-Priest-en-Jarez, France.
- Department of Oncologic and Digestive Surgery, University Hospital of Saint-Etienne, Saint-Priest-en-Jarez, France.
- Department of Radiology, University Hospital of Saint-Etienne, Saint-Priest-en-Jarez, France. remi.grange@chu-st-etienne.fr.
- Department of Radiology, University Hospital of Saint-Étienne, 42055, Saint-Étienne Cedex 2, France. remi.grange@chu-st-etienne.fr.
Förderung
- CHU Saint-Étienne
Zitieren
APA
Morisot, C., Chami Khazraji, I., Habouzit, V., Magand, N., Le Roy, B., El Boukili, I., Boutet, C., Grange, S., & Grange, R. (2026). Precision of Ablation Margin Assessment After Liver Microwave Ablation: A Head-to-Head Comparison of Visual and Software-Assisted Methods. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-026-04528-x
Vancouver
Morisot C, Chami Khazraji I, Habouzit V, Magand N, Le Roy B, El Boukili I, et al. Precision of Ablation Margin Assessment After Liver Microwave Ablation: A Head-to-Head Comparison of Visual and Software-Assisted Methods. CardioVascular and Interventional Radiology. 2026. doi:10.1007/s00270-026-04528-x
BibTeX
@article{Morisot2026,
author = {Morisot, Coline and Chami Khazraji, Idriss and Habouzit, Vincent and Magand, Nicolas and Le Roy, Bertrand and El Boukili, Ilies and Boutet, Claire and Grange, Sylvain and Grange, Rémi},
title = {Precision of Ablation Margin Assessment After Liver Microwave Ablation: A Head-to-Head Comparison of Visual and Software-Assisted Methods},
journal = {CardioVascular and Interventional Radiology},
year = {2026},
doi = {10.1007/s00270-026-04528-x}
}
EUVIMED