Microwave ablation followed by cTACE in 5-cm HCC lesions: does a single-session approach affect liver function?
La radiologia medica · 2024
DOI: 10.1007/s11547-024-01842-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift La radiologia medica, 2024. Verfasst von Chiara Floridi und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126, Ancona, Italy. Hauptthemen laut MEDLINE: Liver Neoplasms, Carcinoma, Hepatocellular, Microwaves, Chemoembolization, Therapeutic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Università Politecnica delle Marche.
Abstract (Originalsprache)
Purpose
Microwave ablation (MWA) and conventional transarterial chemoembolization (cTACE) are locoregional treatments commonly performed in very early, early and intermediate stages of hepatocellular carcinoma (HCC). Despite combined locoregional approaches have shown encouraging results in obtaining complete tumor necrosis, their application in a single session is poorly described. Our aim was to evaluate the safety and efficacy of single-session MWA and cTACE treatment in 5-cm HCCs and its influence on liver function. Materials and methods All 5-cm HCCs treated by MWA and cTACE performed in a single-session in our Interventional Radiology unit between January 2020 and December 2022 were retrospectively recorded and analyzed. Patients with poor or missing pre- and post-treatment imaging were excluded. Technical success, clinical success, and complications rate were examined as primary endpoints. Pre- and post-treatment liver function laboratory parameters were also evaluated.
Results
A total of 15 lesions (mean lesion diameter, 5.0 ± 1.4 cm) in 15 patients (11 men; mean age, 67.1 ± 8.9 years) were retrospectively evaluated. Technical and clinical success were 100% and 73%, respectively. Four (27%) cases of partial response and no cases of progressive or stable disease were recorded. AST and ALT values have found to be significantly higher in post-treatment laboratory tests. No other significant differences between pre- and post-treatment laboratory values were registered. AST and ALT pre- and post-treatment higher differences (ΔAST and ΔALT) were significantly associated with a lower clinical success rate.
Conclusion
MWA and cTACE single-session approach is safe and effective for 5-cm HCCs, without significant liver function impairment. A post-treatment increase in AST and ALT values may be a predictor for clinical failure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126, Ancona, Italy.
- Division of Interventional Radiology, Department of Clinical, Special and Dental Sciences, University Politecnica Delle Marche, 60126, Ancona, Italy.
- Division of Radiology, Department of Radiological Sciences, University Hospital "Azienda Ospedaliero Universitaria Delle Marche", 60126, Ancona, Italy.
- Division of Interventional Radiology, Department of Radiological Sciences, University Politecnica Delle Marche, 60126, Ancona, Italy. laura.cacioppa@gmail.com.
- Division of Interventional Radiology, Department of Clinical, Special and Dental Sciences, University Politecnica Delle Marche, 60126, Ancona, Italy. laura.cacioppa@gmail.com.
- Interventional Radiology Unit, "F. Miulli" Regional General Hospital, 70021, Acquaviva Delle Fonti, Bari, Italy.
Förderung
- Università Politecnica delle Marche
Zitieren
APA
Floridi, C., Cacioppa, L. M., Rossini, N., Macchini, M., Bruno, A., Agostini, A., Consoli, V., Inchingolo, R., Acquafredda, F., Nicolini, D., Schiadà, L., Svegliati Baroni, G., & Candelari, R. (2024). Microwave ablation followed by cTACE in 5-cm HCC lesions: does a single-session approach affect liver function?. La radiologia medica. https://doi.org/10.1007/s11547-024-01842-7
Vancouver
Floridi C, Cacioppa LM, Rossini N, Macchini M, Bruno A, Agostini A, et al. Microwave ablation followed by cTACE in 5-cm HCC lesions: does a single-session approach affect liver function?. La radiologia medica. 2024. doi:10.1007/s11547-024-01842-7
BibTeX
@article{Floridi2024,
author = {Floridi, Chiara and Cacioppa, Laura Maria and Rossini, Nicolò and Macchini, Marco and Bruno, Alessandra and Agostini, Andrea and Consoli, Valeria and Inchingolo, Riccardo and Acquafredda, Fabrizio and Nicolini, Daniele and Schiadà, Laura and Svegliati Baroni, Gianluca and Candelari, Roberto},
title = {Microwave ablation followed by cTACE in 5-cm HCC lesions: does a single-session approach affect liver function?},
journal = {La radiologia medica},
year = {2024},
doi = {10.1007/s11547-024-01842-7}
}
EUVIMED