EUVIMEDEUVIMED entdecken
Multizentrische StudieOpen Access · CC BY 4.0

Multicenter and inter-software evaluation of ablative margins after thermal ablation of colorectal liver metastases

Gregor Laimer, Koen H M Verdonschot, Lina Kopf, Susan van der Lei, Yannick Scharll, Gerjon Hannink, Sjoerd F M Jenniskens, Martijn R Meijerink, Reto Bale, Christiaan G Overduin

European Radiology · 02.08.2024 · 35 (2) · 1046-1056

DOI: 10.1007/s00330-024-10956-5 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift European Radiology, online erschienen am 02.08.2024. Verfasst von Gregor Laimer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Interventional Oncology, Stereotaxy and Robotics, Medical University Innsbruck, Innsbruck, Austria. Hauptthemen laut MEDLINE: Liver Neoplasms, Colorectal Neoplasms, Tomography, X-Ray Computed, Margins of Excision. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the association between minimal ablative margin (MAM) and local tumor progression (LTP) following CT-guided thermal ablation of colorectal liver metastases (CRLM) in a multicenter cohort and across two confirmation software. Materials and methods This multicenter retrospective study included patients who underwent CT-guided radiofrequency or microwave ablation for CRLM between 2009 and 2021 in three institutions. Three-dimensional (3D) MAM was retrospectively assessed using dedicated ablation confirmation software by automatic non-rigid (Ablation-fit) or semi-automatic rigid co-registration (SAFIR) of intraprocedural pre- and post-ablation contrast-enhanced CT scans by two independent reader teams blinded to patient outcomes. LTP was assessed on a per-tumor basis. Factors associated with LTP-free survival were assessed using multivariable Cox regression analysis.

Results

Overall, 113 patients (mean age: 67 ± 10 years; 78 men) who underwent thermal ablation for 189 CRLM (mean diameter: 1.9 ± 1.1 cm) met the inclusion criteria. 173/189 (92%) CRLM could be successfully analyzed using both software. Over a median follow-up of 31 months (IQR: 22–47), 21 of 173 CRLM (12.1%) developed LTP. On multivariable analysis, 3D MAM was independently associated with LTP in both software (Ablation-fit: HR 0.47, 95% CI: 0.36–0.61, p < 0.001; SAFIR: HR 0.42, 95% CI: 0.32–0.55, p < 0.001). No LTP was observed in CRLM ablated with MAM ≥ 4 mm (Ablation-fit) and ≥ 5 mm (SAFIR). The per-tumor median absolute difference in MAM quantification between both software was 2 mm (IQR: 1–3).

Conclusion

MAM was independently associated with LTP after thermal ablation of CRLM across multicenter data and two confirmation software. Ablations achieving a MAM ≥ 5 mm were associated with local control in both software. Clinical relevance statement MAMs from intraprocedural contrast-enhanced CT were independently associated with LTP after thermal ablation of CRLM across multicenter data and two confirmation software, with a margin ≥ 5 mm associated with local control in both software. Key Points Sufficient ablative margins are critical for local control following thermal ablation of CRLM . Intraprocedural CT-derived MAM was the only independent factor associated with LTP across two confirmation software. No LTP was observed in CRLM ablated with a MAM ≥ 5 mm .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Liver NeoplasmsColorectal NeoplasmsTomography, X-Ray ComputedMargins of ExcisionSoftwareRadiofrequency AblationHumansMaleFemaleAgedRetrospective StudiesMiddle AgedMicrowavesTreatment Outcome

Stichwörter der Autor:innen

Imaging (three-dimensional)Liver neoplasmsRadiofrequency ablationTreatment outcome

Autor:innen und Institutionen

  • Department of Radiology, Interventional Oncology, Stereotaxy and Robotics, Medical University Innsbruck, Innsbruck, Austria.
  • Department of Medical Imaging, Radiology, Radboud University Medical Center, Nijmegen, Netherlands.
  • Department of Radiology and Nuclear Medicine, Amsterdam UMC location Vrije Universiteit Amsterdam, Amsterdam, Netherlands.
  • Department of Medical Imaging, Radiology, Radboud University Medical Center, Nijmegen, Netherlands. kristian.overduin@radboudumc.nl.

Zitieren

APA

Laimer, G., Verdonschot, K. H. M., Kopf, L., van der Lei, S., Scharll, Y., Hannink, G., Jenniskens, S. F. M., Meijerink, M. R., Bale, R., & Overduin, C. G. (2024). Multicenter and inter-software evaluation of ablative margins after thermal ablation of colorectal liver metastases. European Radiology, 35(2), 1046-1056. https://doi.org/10.1007/s00330-024-10956-5

Vancouver

Laimer G, Verdonschot KHM, Kopf L, van der Lei S, Scharll Y, Hannink G, et al. Multicenter and inter-software evaluation of ablative margins after thermal ablation of colorectal liver metastases. European Radiology. 2024;35(2):1046-1056. doi:10.1007/s00330-024-10956-5

BibTeX
@article{Laimer2024,
  author = {Laimer, Gregor and Verdonschot, Koen H M and Kopf, Lina and van der Lei, Susan and Scharll, Yannick and Hannink, Gerjon and Jenniskens, Sjoerd F M and Meijerink, Martijn R and Bale, Reto and Overduin, Christiaan G},
  title = {Multicenter and inter-software evaluation of ablative margins after thermal ablation of colorectal liver metastases},
  journal = {European Radiology},
  year = {2024},
  volume = {35},
  number = {2},
  pages = {1046--1056},
  doi = {10.1007/s00330-024-10956-5}
}
Kostenlos starten →