Feasibility and Safety of Percutaneous Puncture Guided by a 5G-Based Telerobotic Ultrasound System: An Experimental Study

Lanling Yang, Shaobo Duan, Ye Zhang, Liuwei Hao, Shuaiyang Wang, Zhi Zou, Yanshan Hu, Si Chen, Yiwen Hu, Lianzhong Zhang

CardioVascular and Interventional Radiology · 2024

DOI: 10.1007/s00270-024-03681-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2024. Verfasst von Lanling Yang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, 450003, Henan, China. Hauptthemen laut MEDLINE: Feasibility Studies, Punctures, Ultrasonography, Interventional, Phantoms, Imaging. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Health Commission of Henan Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To evaluate the feasibility and safety of percutaneous puncture guided by a 5th generation mobile communication technology (5G)-based telerobotic ultrasound system in phantom and animal experiments. MATERIALS AND METHODS: In the phantom experiment, 10 simulated lesions were punctured, once at each of two angles for each lesion, under the guidance of a telerobotic ultrasound system and ultrasound-guided freehand puncture. Student's t test was used to compare the two methods in terms of puncture accuracy, total operation duration, and puncture duration. In the animal experiment, under the guidance of the telerobotic ultrasound system, an 18G puncture needle was used to puncture 3 target steel beads in the liver, right kidney, and right gluteal muscle, respectively. The animal experiment had no freehand ultrasound-guided control group. After puncture, a CT scan was performed to verify the position of the puncture needle in relation to the target, and the complications and puncture duration, etc., were recorded. RESULTS: In the phantom experiment, the mean accuracies of puncture under telerobotic ultrasound guidance and conventional ultrasound guidance were 1.8 ± 0.3 mm and 1.6 ± 0.3 mm (P = 0.09), respectively; therefore, there was no significant difference in the accuracy of the two guide methods. In the animal experiment, the first-attempt puncture success (the needle tip close to the target) rate was 93%. Polypnea occurred during one puncture. No other intraoperative or postoperative complications were observed. CONCLUSION: Puncture guided by a 5G-based telerobotic ultrasound system has shown good feasibility and safety in phantom and animal experiments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Feasibility StudiesPuncturesUltrasonography, InterventionalPhantoms, ImagingAnimalsLiverKidneyTomography, X-Ray Computed

Stichwörter der Autor:innen

5GInterventional ultrasoundRemote ultrasoundTelerobotic

Autor:innen und Institutionen

  • Zhengzhou University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, 450003, Henan, China.
  • Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou, 450003, Henan, China.
  • Department of Ultrasound, Henan Key Laboratory for Ultrasound Molecular Imaging and Artificial Intelligence Medicine, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's…
  • Henan University People's Hospital, Henan Provincial People's Hospital, Zhengzhou, 450003, Henan, China.
  • Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou, 450003, Henan, China. zlz8777@zzu.edu.cn.
  • Department of Rehabilitation, Henan Rehabilitation Clinical Medicine Research Center, Henan Provincial People's Hospital, Zhengzhou University People's Hospital, Henan University People's Hospital, Zhengzhou, 450003, He…

Förderung

  • Health Commission of Henan Province
  • National Natural Science Foundation of China

Zitieren

APA

Yang, L., Duan, S., Zhang, Y., Hao, L., Wang, S., Zou, Z., Hu, Y., Chen, S., Hu, Y., & Zhang, L. (2024). Feasibility and Safety of Percutaneous Puncture Guided by a 5G-Based Telerobotic Ultrasound System: An Experimental Study. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-024-03681-5

Vancouver

Yang L, Duan S, Zhang Y, Hao L, Wang S, Zou Z, et al. Feasibility and Safety of Percutaneous Puncture Guided by a 5G-Based Telerobotic Ultrasound System: An Experimental Study. CardioVascular and Interventional Radiology. 2024. doi:10.1007/s00270-024-03681-5

BibTeX
@article{Yang2024,
  author = {Yang, Lanling and Duan, Shaobo and Zhang, Ye and Hao, Liuwei and Wang, Shuaiyang and Zou, Zhi and Hu, Yanshan and Chen, Si and Hu, Yiwen and Zhang, Lianzhong},
  title = {Feasibility and Safety of Percutaneous Puncture Guided by a 5G-Based Telerobotic Ultrasound System: An Experimental Study},
  journal = {CardioVascular and Interventional Radiology},
  year = {2024},
  doi = {10.1007/s00270-024-03681-5}
}
Kostenlos starten →