‘Post-Close’ Femoral Arterial Haemostasis at Endovascular Aneurysm Repair using a Dedicated Large-Bore Vascular Closure Device: A Prospective Real-World Audit

A Chaudhuri

CardioVascular and Interventional Radiology · 2023

DOI: 10.1007/s00270-023-03437-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift CardioVascular and Interventional Radiology, 2023. Verfasst von A Chaudhuri. Beteiligte Einrichtung: Bedfordshire-Milton Keynes Vascular Centre, Bedfordshire Hospitals NHS Foundation Trust, Kempston Road, Bedford, MK42 9DJ, UK. a.chaudhuri@ntlworld.c…. Hauptthemen laut MEDLINE: Vascular Closure Devices, Aortic Aneurysm, Abdominal, Endovascular Procedures, Blood Vessel Prosthesis Implantation. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Percutaneous access for endovascular aneurysm repair (EVAR) is commonplace, with its attendant benefits. The combination of continued reduction in device profile and evolution of vascular closure device (VCD) design drives successful and safe percutaneous EVAR. A new such VCD is the MANTA Large-Bore Closure Device designed in two iterations for closure of arterial defects from 10 to 25F. We present a prospective audit of 131 large-bore femoral closures using an 'all-comers' approach to device selection. MATERIALS AND METHODS: One hundred and thirty-one large-bore femoral arterial defects were analysed. Both 14F and 18F MANTA VCDs were deployed in this series as per instructions for use. Primary objectives were technical success, particularly successful deployment, and haemostasis achieved. Failures were denoted as failure to deploy; failure to achieve haemostasis was denoted as active bleeding, haematoma, or pseudoaneurysm formation requiring intervention. Later complications assessed were vessel occlusion/thrombosis or stenosis. RESULTS: Seventy-six patients (65 males and 11 females, age 75.2 ± 8.7 years) underwent a range of procedures including EVAR (n = 66), TEVAR (n = 2), and reinterventions (n = 8) requiring large-bore percutaneous femoral arterial access in 131 groins. Of these, the 14F MANTA VCD was used in 61 closures (defects ranging from 12 to 18F) and the 18F in 70 closures (defects ranging from 16 to 24F). Deployments achieved successful haemostasis in 120 (91.6%), and failures occurred in 11(8.4%) groins. CONCLUSIONS: This study indicates that a post-close approach using the novel MANTA Large-Bore Closure Device can be undertaken successfully to close a range of large-bore femoral arterial defects at EVAR/TEVAR with an acceptable rate of complications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vascular Closure DevicesAortic Aneurysm, AbdominalEndovascular ProceduresBlood Vessel Prosthesis ImplantationMaleFemaleHumansAgedAged, 80 and overEndovascular Aneurysm RepairFemoral ArteryTreatment OutcomePuncturesHemostasisHemostatic TechniquesRetrospective Studies

Stichwörter der Autor:innen

Large-bore femoral accessOutcomes auditPercutaneous EVARPost-closeVascular closure devices

Autor:innen und Institutionen

  • Bedfordshire-Milton Keynes Vascular Centre, Bedfordshire Hospitals NHS Foundation Trust, Kempston Road, Bedford, MK42 9DJ, UK. a.chaudhuri@ntlworld.com.

Zitieren

APA

Chaudhuri, A. (2023). ‘Post-Close’ Femoral Arterial Haemostasis at Endovascular Aneurysm Repair using a Dedicated Large-Bore Vascular Closure Device: A Prospective Real-World Audit. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-023-03437-7

Vancouver

Chaudhuri A. ‘Post-Close’ Femoral Arterial Haemostasis at Endovascular Aneurysm Repair using a Dedicated Large-Bore Vascular Closure Device: A Prospective Real-World Audit. CardioVascular and Interventional Radiology. 2023. doi:10.1007/s00270-023-03437-7

BibTeX
@article{Chaudhuri2023,
  author = {Chaudhuri, A},
  title = {‘Post-Close’ Femoral Arterial Haemostasis at Endovascular Aneurysm Repair using a Dedicated Large-Bore Vascular Closure Device: A Prospective Real-World Audit},
  journal = {CardioVascular and Interventional Radiology},
  year = {2023},
  doi = {10.1007/s00270-023-03437-7}
}
Kostenlos starten →