A single center study of the efficacy and safety of Pro-Glide used for closure in thoracic endovascular aortic repair in patients with previous groin intervention
Vascular · 2025
DOI: 10.1177/17085381241236560 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vascular, 2025. Verfasst von Recep Gulmez und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University of Health Sciences, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanb…. Hauptthemen laut MEDLINE: Aorta, Thoracic, Blood Vessel Prosthesis Implantation, Endovascular Procedures, Groin. Die Arbeit nennt 19 Literaturangaben.
Abstract (Originalsprache)
Background
This study aimed to evaluate the efficacy and safety of Pro-Glide, a suture-mediated vascular closure device, regarding technical success and complications in patients who had undergone aortic intervention and had previous groin intervention (PGI).
Methods
One hundred and thirty-five patients who underwent percutaneous thoracic endovascular aortic repair via the femoral artery and were closed with the Pro-Glide device were analyzed retrospectively. PGI was defined as a history of open surgical access to the femoral artery or wide sheath (>18 F) placement due to endovascular or valvular intervention. The patients were divided into two groups 38 cases with PGI and 97 cases without PGI.
Results
The overall success rate of closure of the femoral artery with Pro-Glide was not statistically significant between the two groups (93.8% vs 92.1%, p = .711). Sheath sizes were compared between the groups and PGI (+) group had significantly higher sheath sizes compared to PGI (−) group (24.3 ± 1.1 F vs 23.8 ± 1.0 F, p = .011). Three patients in the PGI (+) group and six patients in the PGI (−) group experienced technical failure of the percutaneous femoral approach. Femoral complications were seen after the procedures in four patients in the PGI (+) group and four in the PGI (−) group. The PGI (+) group had a higher complication rate when compared to the PGI (−) group; however, this was not statistically significant ( p = .181).
Conclusion
The present study was conducted on a significantly larger sample compared to previous studies and the findings suggest that the Pro-Glide vascular closure device is a safe option for patients with a history of PGI and may not be considered as a contraindication.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University of Health Sciences, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey.
- Department of Cardiology, Liv Bahcesehir Hospital, Faculty of Medicine, Istinye University, Istanbul, Turkey.
ORCID-Profile: Mehmet Altunova, Ahmet Anil Sahin
Zitieren
APA
Gulmez, R., Altunova, M., Sahin, A. A., & Celik, O. (2025). A single center study of the efficacy and safety of Pro-Glide used for closure in thoracic endovascular aortic repair in patients with previous groin intervention. Vascular. https://doi.org/10.1177/17085381241236560
Vancouver
Gulmez R, Altunova M, Sahin AA, Celik O. A single center study of the efficacy and safety of Pro-Glide used for closure in thoracic endovascular aortic repair in patients with previous groin intervention. Vascular. 2025. doi:10.1177/17085381241236560
BibTeX
@article{Gulmez2025,
author = {Gulmez, Recep and Altunova, Mehmet and Sahin, Ahmet Anil and Celik, Omer},
title = {A single center study of the efficacy and safety of Pro-Glide used for closure in thoracic endovascular aortic repair in patients with previous groin intervention},
journal = {Vascular},
year = {2025},
doi = {10.1177/17085381241236560}
}
EUVIMED