A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair
Vascular · 2026
DOI: 10.1177/17085381261429288 ↗Kurz gefasst
Fachartikel in der Zeitschrift Vascular, 2026. Verfasst von Sven Ross Mathisen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Vascular Surgery, Innlandet Hospital TrustHamar, Brumunddal, Norway. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Aortic Aneurysm, Abdominal, Vascular Closure Devices, Hemostatic Techniques. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
Objectives
To evaluate efficacy and safety of percutaneous-endovascular aneurysm repair (p-EVAR) where large-bore access puncture holes were closed with a suture mediated closure device (SMCD) in all eligible patients.
Methods
A single-center cohort of prospectively collected data in an Internal Quality Control Registry (IQCR). An “All Comers” cohort of 368 patients with 736 access groins was assessed. All abdominal aortic aneurysm (AAA) patients eligible for p-EVAR after CTA evaluation were included. Patients with stenosis and occlusions requiring vascular Interventions during EVAR were excluded. The groins were stratified into two groups: low-profile (12Fr – 16Fr) and high-profile introducers (18Fr - 20Fr). PerClose ProGlide (Abbott Cardiovascular, IL, USA) and later the newer version PerClose ProStyle (Abbott Cardiovascular, IL, USA) SMCD devices were assessed. Primary endpoints were: Primary ProGlide technical success and Primary assisted percutaneous and non-invasive technical success. Secondary cutdown was an exclusions criterion. Safety endpoints were Freedom from early peri-operative and late 30-day groin access complications requiring vascular surgical intervention.
Results
Primary technical success was achieved in 66.4 % (473/712) groins . Primary assisted percutaneous and non-invasive technical success was achieved in 32.2 % (229/712) groins. Continuous hemorrhage in 1.4 % (10/712) groins required a cutdown. 98.6 % (712/736) of the groins were successfully closed percutaneously. Median age was 76 years (IQR 71, 80). 78.8 % were male. 92 % (330/368) of the p-EVAR were elective. Median AAA diameter was 57mm (IQR 53, 63). Few groins required surgical intervention. No statically significant differences were found between the PerClose ProGlide and the ProStyle (p < .05).
Conclusions
Percutaneous closure is efficient and safe. Low-profile introducers and EVAR components (12Fr – 16Fr) had slightly better primary technical and assisted technical success. 83.5 % of the patient groins were treated with low-profile introducers reflecting the drive in the vascular field toward lower-profile devices. No statistical difference between groups was observed for primary technical success and complication rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Vascular Surgery, Innlandet Hospital TrustHamar, Brumunddal, Norway.
- Department of Vascular Surgery, University of Oslo, Oslo, Norway.
- Faculty of Medicine, Department of Clinical Medicine, University of Oslo, Oslo, Norway.
ORCID-Profile: Sven Ross Mathisen, Simen Tveten Berge
Zitieren
APA
Mathisen, S. R., & Berge, S. T. (2026). A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair. Vascular. https://doi.org/10.1177/17085381261429288
Vancouver
Mathisen SR, Berge ST. A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair. Vascular. 2026. doi:10.1177/17085381261429288
BibTeX
@article{Mathisen2026,
author = {Mathisen, Sven Ross and Berge, Simen Tveten},
title = {A seven-year single-center experience with large-bore percutaneous closure in endovascular aneurysm repair},
journal = {Vascular},
year = {2026},
doi = {10.1177/17085381261429288}
}
EUVIMED