Assessing glenoid orientation on the axillary view: a novel technique using the posterolateral acromion-to-coracoid line
International Orthopaedics · 2025
DOI: 10.1007/s00264-025-06661-7 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift International Orthopaedics, 2025. Verfasst von Michael Hachadorian und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery and Sports Medicine, University of Washington, Seattle, USA. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Joint, Glenoid Cavity, Postoperative Care. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: University of Washington’s Douglas T. Harryman II/Depuy Endowed Chair for Shoulder Research and The Rick and Anne Matsen Endowed Professorship for Shoulder Res….
Abstract (Originalsprache)
PURPOSE: In shoulder arthroplasty, three-dimensional computed tomography (3D CT) has become the gold standard for preoperative version assessment. Meanwhile, postoperative version is usually evaluated using radiographs (XR), in particular an axillary view, in which the view of the scapular body is often truncated, preventing the scapular plane from being used as a reference. This study introduces the posterolateral acromion-to-coracoid (PLAC) line, which can be assessed on a standard truncated axillary radiograph. MATERIALS AND METHODS: Forty-six shoulders were studied. Four angles were measured including 3D CT (CT Version), 3D CT PLAC line to glenoid face angle (CT PLAC-GFA), 2) radiographic PLAC line to glenoid face angle (XR PLAC-GFA), and 3) the radiographic glenoid vault line to glenoid face angle (XR GV-GFA). Variation and linear relationship between these angles were calculated. RESULTS: The mean difference between CT PLAC-GFA and XR PLAC-GFA was 1.0º (95% CI -0.7 to 2.8)(IQR = 8.5º, -3.0º to 5.4º), with a strong correlation on linear regression (R2 = 0.76, p < 0.001). XR PLAC-GFA and XR GV-GFA demonstrated strong correlations with CT measured version (R2 = 0.72 and 0.70, respectively; p < 0.001). Inter-rater reliability was excellent for all metrics (ICC ≥ 0.93). CONCLUSIONS: The PLAC and the glenoid vault lines are highly reproducible references on truncated axillary views. These alternative reference lines allow accurate comparison of preoperative and postoperative glenoid orientation using standard axillary radiographs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery and Sports Medicine, University of Washington, Seattle, USA.
- Anderson Orthopaedic Clinic, Arlington, USA.
- Department of Orthopaedic Surgery and Sports Medicine, University of Washington, Seattle, USA. jehsu@uw.edu.
Förderung
- University of Washington’s Douglas T. Harryman II/Depuy Endowed Chair for Shoulder Research and The Rick and Anne Matsen Endowed Professorship for Shoulder Res…
Zitieren
APA
Hachadorian, M., Sheth, M., Kahsai, E., Whitson, A., Schiffman, C., Matsen, F., & Hsu, J. (2025). Assessing glenoid orientation on the axillary view: a novel technique using the posterolateral acromion-to-coracoid line. International Orthopaedics. https://doi.org/10.1007/s00264-025-06661-7
Vancouver
Hachadorian M, Sheth M, Kahsai E, Whitson A, Schiffman C, Matsen F, et al. Assessing glenoid orientation on the axillary view: a novel technique using the posterolateral acromion-to-coracoid line. International Orthopaedics. 2025. doi:10.1007/s00264-025-06661-7
BibTeX
@article{Hachadorian2025,
author = {Hachadorian, Michael and Sheth, Mihir and Kahsai, Ermyas and Whitson, Anastasia and Schiffman, Corey and Matsen, Frederick and Hsu, Jason},
title = {Assessing glenoid orientation on the axillary view: a novel technique using the posterolateral acromion-to-coracoid line},
journal = {International Orthopaedics},
year = {2025},
doi = {10.1007/s00264-025-06661-7}
}