EUVIMEDEUVIMED entdecken
Crossref

Quantitative equivalence of Quantitative Imaging Biomarkers Alliance (QIBA)-2023- and QIBA-2020-compliant MR elastography protocols for liver stiffness assessment

Takahisa Tokimori, Satoshi Saitoh, Shingo Ohira, Hidesato Suzuki, Isao Kurita, Masakatsu Tano, Takuyo Kozuka

Abdominal Radiology · 2026

DOI: 10.1007/s00261-026-05490-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, 2026. Verfasst von Takahisa Tokimori und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Toranomon Hospital, Tokyo, Japan. takahisa1877@yahoo.co.jp. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Magnetic Resonance Imaging, Liver Cirrhosis. Die Arbeit nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Magnetic resonance elastography (MRE) has become an essential noninvasive tool for quantitative assessment of liver stiffness and fibrosis staging, particularly in patients with steatotic liver disease. To enhance standardization and reproducibility, the Quantitative Imaging Biomarkers Alliance (QIBA) released an updated liver MRE profile in 2023, replacing the previous 2020 version. However, the quantitative continuity between these two protocol versions, particularly for longitudinal liver stiffness measurements, has not been sufficiently validated. This study aimed to evaluate the quantitative equivalence and clinical utility of a QIBA-2023-compliant MRE protocol through direct comparison with the conventional QIBA-2020-compliant protocol in the same subjects, with emphasis on longitudinal liver stiffness assessment and image quality. METHODS: This retrospective study included 130 consecutive patients who underwent liver MRE in 2024. Each patient was examined using both the conventional QIBA-2020-compliant protocol and the updated QIBA-2023-compliant protocol during a single imaging session. Liver stiffness values were compared using Spearman correlation, Bland-Altman analysis, and intraclass correlation coefficients (ICC). Measurement variability and repeatability were evaluated with reference to QIBA-defined repeatability metrics. Image quality was evaluated by comparing region-of-interest (ROI) size and measurable liver parenchymal area excluding low-confidence (cross-hatched) regions. RESULTS: Mean liver stiffness values were 3.62 ± 1.81 kPa for the conventional protocol and 3.69 ± 1.94 kPa for the updated protocol, with a very strong correlation (r = 0.98, p < 0.001) and excellent agreement (ICC = 0.988). Bland-Altman analysis showed a minimal mean bias of 0.07 kPa with 95% limits of agreement from - 0.48 to 0.63 kPa, which were within established MRE repeatability thresholds. Although the difference between protocols reached statistical significance, the absolute difference was not clinically meaningful. The updated protocol produced significantly larger ROIs and a greater measurable liver parenchymal area, consistent with reduced imaging artifacts and improved image quality. CONCLUSIONS: The QIBA-2023-compliant MRE protocol demonstrates quantitative equivalence to the conventional QIBA-2020 protocol while offering improved artifact suppression and expanded measurable liver parenchyma. These findings support use of the updated protocol for reliable longitudinal liver stiffness assessment without compromising diagnostic performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesMagnetic Resonance ImagingLiver CirrhosisHumansFemaleReproducibility of ResultsMaleRetrospective StudiesMiddle AgedAdultAgedLiverBiomarkers

Stichwörter der Autor:innen

Liver stiffnessLongitudinal assessmentMagnetic resonance elastographyQIBAReproducibility

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Department of Radiology, Toranomon Hospital, Tokyo, Japan. takahisa1877@yahoo.co.jp.
  • Department of Hepatology, Toranomon Hospital, Tokyo, Japan. saitoh31103104@gmail.com.
  • Department of Radiology, Toranomon Hospital, Tokyo, Japan. ueshin55@gmail.com.
  • Department of Radiological Science, Graduate School of Human Health Science, Tokyo Metropolitan University, Tokyo, Japan. ueshin55@gmail.com.
  • Department of Radiology, Toranomon Hospital, Tokyo, Japan.
  • Department of Radiation Oncology, Toranomon Hospital, Tokyo, Japan.

Zitieren

APA

Tokimori, T., Saitoh, S., Ohira, S., Suzuki, H., Kurita, I., Tano, M., & Kozuka, T. (2026). Quantitative equivalence of Quantitative Imaging Biomarkers Alliance (QIBA)-2023- and QIBA-2020-compliant MR elastography protocols for liver stiffness assessment. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05490-5

Vancouver

Tokimori T, Saitoh S, Ohira S, Suzuki H, Kurita I, Tano M, et al. Quantitative equivalence of Quantitative Imaging Biomarkers Alliance (QIBA)-2023- and QIBA-2020-compliant MR elastography protocols for liver stiffness assessment. Abdominal Radiology. 2026. doi:10.1007/s00261-026-05490-5