EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Acquisition Efficiency and Technical Repeatability of Dual‐Frequency 3D Vector MR Elastography of the Liver

Caixin Qiu iD, Kevin J Glaser, Nana Owusu, Jiahui Li, Hao Wu, Sudhakar K Venkatesh, Armando Manduca, Richard L Ehman, Meng Yin iD

Journal of Magnetic Resonance Imaging · 2025

DOI: 10.1002/jmri.29493 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Caixin Qiu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Tianjin First Central Hospital, Tianjin, China. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques, Liver, Imaging, Three-Dimensional, Magnetic Resonance Imaging. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIDDK NIH HHS, NIAAA NIH HHS, NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

MR elastography (MRE) at 60 Hz is widely used for staging liver fibrosis. MRE with lower frequencies may provide inflammation biomarkers.

Purpose

To establish a practical simultaneous dual‐frequency liver MRE protocol at both 30 Hz and 60 Hz during a single examination and validate the occurrence of second harmonic waves at 30 Hz. Study Type Retrospective. Subjects One hundred six patients (48 females, age: 50.0 ± 13.4 years) were divided as follows: Cohort One (15 patients with chronic liver disease [CLD] and 25 healthy volunteers) with simultaneous dual‐frequency MRE. Cohort Two (66 patients with CLD) with second harmonic MRE. Field Strength/Sequence 3‐T, single‐ or dual‐frequency MRE at 30 Hz and 60 Hz. Assessment Liver stiffness (LS) in both cohorts was evaluated with manually placed volumetric ROIs by two independent analyzers. Image quality was assessed by three independent readers on a 4‐point scale (0–3: none/failed, fair, moderate, excellent) based on the depth of wave propagation with 1/3 incremental penetration. The success rate was derived from the percentage of nonzero quality scores. Statistical Tests Measurement agreement, bias, and repeatability of LS were assessed using intraclass correlation coefficients (ICCs), Bland–Altman plots, and repeatability coefficient (RC). Mann–Whitney U tests were used to evaluate the differences in image quality between different methods. A P ‐value 0.90). The quality scores for the second harmonic wave images were lower than those from the conventional MRE ( Z = −4.523). Data Conclusion Compared with conventional and second harmonic methods, simultaneous dual‐frequency had better image quality, high success rate and the advantage of intrinsic co‐registration, while the second harmonic method can be an alternative if custom waveform is not available. Evidence Level 3 Technical Efficacy Stage 1

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesLiverImaging, Three-DimensionalMagnetic Resonance ImagingLiver CirrhosisLiver DiseasesHumansFemaleMiddle AgedReproducibility of ResultsMaleAdultRetrospective StudiesAgedImage Processing, Computer-Assisted

Stichwörter der Autor:innen

MREchronic liver diseasedual‐frequencysecond harmonic

Autor:innen und Institutionen

  • Department of Radiology, Tianjin First Central Hospital, Tianjin, China.
  • Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.

ORCID-Profile: Caixin Qiu, Meng Yin

Förderung

  • NIDDK NIH HHS
  • NIAAA NIH HHS
  • NIBIB NIH HHS
  • Tianjin Health Department Research Project, China
  • Center for Individualized Medicine (CIM) at Mayo Clinic
  • Department of Defense (DoD)
  • U.S. Department of Defense

Zitieren

APA

Qiu, C., Glaser, K. J., Owusu, N., Li, J., Wu, H., Venkatesh, S. K., Manduca, A., Ehman, R. L., & Yin, M. (2025). Acquisition Efficiency and Technical Repeatability of Dual‐Frequency 3D Vector MR Elastography of the Liver. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29493

Vancouver

Qiu C, Glaser KJ, Owusu N, Li J, Wu H, Venkatesh SK, et al. Acquisition Efficiency and Technical Repeatability of Dual‐Frequency 3D Vector MR Elastography of the Liver. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29493

BibTeX
@article{Qiu2025,
  author = {Qiu, Caixin and Glaser, Kevin J and Owusu, Nana and Li, Jiahui and Wu, Hao and Venkatesh, Sudhakar K and Manduca, Armando and Ehman, Richard L and Yin, Meng},
  title = {Acquisition Efficiency and Technical Repeatability of Dual‐Frequency 3D Vector MR Elastography of the Liver},
  journal = {Journal of Magnetic Resonance Imaging},
  year = {2025},
  doi = {10.1002/jmri.29493}
}
Kostenlos starten →