Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT

Josua A Decker, Judith Becker, Mark Härting, Bertram Jehs, Franka Risch, Luca Canalini, Claudia Wollny, Christian Scheurig-Muenkler, Thomas Kroencke iD, Florian Schwarz, Stefanie Bette

Abdominal Radiology · 05.10.2023 · 49 (1) · 103-116

DOI: 10.1007/s00261-023-04042-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Abdominal Radiology, online erschienen am 05.10.2023. Verfasst von Josua A Decker und 10 weiteren Autor:innen. Beteiligte Einrichtung: Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Stenglinstr. 2, 86156, Augsburg, …. Hauptthemen laut MEDLINE: Radiography, Dual-Energy Scanned Projection, Pancreatic Neoplasms, Carcinoma, Pancreatic Ductal. Die Arbeit wurde bisher 43-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Augsburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To analyze the conspicuity of pancreatic ductal adenocarcinoma (PDAC) in virtual monoenergetic images (VMI) on a novel photon-counting detector CT (PCD-CT) in comparison to energy-integrating CT (EID-CT).

Methods

Inclusion criteria comprised initial diagnosis of PDAC (reference standard: histopathological analysis) and standardized contrast-enhanced CT imaging either on an EID-CT or a PCD-CT. Patients were excluded due to different histopathological diagnosis or missing tumor delineation on CT. On the PCD-CT, 40–190 keV VMI reconstructions were generated. Image noise, tumor-to-pancreas ratio (TPR) and contrast-to-noise ratio (CNR) were analyzed by ROI-based measurements in arterial and portal venous contrast phase. Two board-certified radiologist evaluated image quality and tumor delineation at both, EID-CT and PCD-CT (40 and 70 keV).

Results

Thirty-eight patients (mean age 70.4 years ± 10.3 [range 45–91], 27 males; PCD-CT: n=19, EID-CT: n=19) were retrospectively included. On the PCD-CT, tumor conspicuity (reflected by low TPR and high CNR) was significantly improved at low-energy VMI series (≤ 70 keV compared to > 70 keV), both in arterial and in portal venous contrast phase (P < 0.001), reaching the maximum at 40 keV. Comparison between PCD-CT and EID-CT showed significantly higher CNR on the PCD-CT in portal venous contrast phase at < 70 keV (P < 0.016). On the PCD-CT, tumor conspicuity was improved in portal venous contrast phase compared to arterial contrast phase especially at the lower end of the VMI spectrum (≤ 70 keV). Qualitative analysis revealed that tumor delineation is improved in 40 keV reconstructions compared to 70 keV reconstructions on a PCD-CT.

Conclusion

PCD-CT VMI reconstructions (≤ 70 keV) showed significantly improved conspicuity of PDAC in quantitative and qualitative analysis in both, arterial and portal venous contrast phase, compared to EID-CT, which may be important for early detection of tumor tissue in clinical routine. Tumor delineation was superior in portal venous contrast phase compared to arterial contrast phase.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiography, Dual-Energy Scanned ProjectionPancreatic NeoplasmsCarcinoma, Pancreatic DuctalMaleHumansAgedRetrospective StudiesSignal-To-Noise RatioTomography, X-Ray ComputedRadiographic Image Interpretation, Computer-Assisted

Stichwörter der Autor:innen

Contrast-enhanced CTPancreatic ductal adenocarcinomaPhoton-counting detector computed tomographyVirtual monoenergetic imaging

Autor:innen und Institutionen

  • Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany.
  • Diagnostic and Interventional Radiology, Faculty of Medicine, University Hospital Augsburg, University of Augsburg, Stenglinstr. 2, 86156, Augsburg, Germany. thomas.kroencke@uk-augsburg.de.
  • Centre for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, Universitätsstr. 2, 86159, Augsburg, Germany. thomas.kroencke@uk-augsburg.de.
  • Medical Faculty, Ludwig Maximilian University Munich, Bavariaring 19, 80336, Munich, Germany.
  • Institute for Radiology, DONAUISAR Hospital Deggendorf-Dingolfing-Landau, Perlasberger Str. 41, 94469, Deggendorf, Germany.

ORCID-Profile: Thomas Kroencke

Förderung

  • Universität Augsburg

Zitieren

APA

Decker, J. A., Becker, J., Härting, M., Jehs, B., Risch, F., Canalini, L., Wollny, C., Scheurig-Muenkler, C., Kroencke, T., Schwarz, F., & Bette, S. (2023). Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT. Abdominal Radiology, 49(1), 103-116. https://doi.org/10.1007/s00261-023-04042-5

Vancouver

Decker JA, Becker J, Härting M, Jehs B, Risch F, Canalini L, et al. Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT. Abdominal Radiology. 2023;49(1):103-116. doi:10.1007/s00261-023-04042-5

BibTeX
@article{Decker2023,
  author = {Decker, Josua A and Becker, Judith and Härting, Mark and Jehs, Bertram and Risch, Franka and Canalini, Luca and Wollny, Claudia and Scheurig-Muenkler, Christian and Kroencke, Thomas and Schwarz, Florian and Bette, Stefanie},
  title = {Optimal conspicuity of pancreatic ductal adenocarcinoma in virtual monochromatic imaging reconstructions on a photon-counting detector CT: comparison to conventional MDCT},
  journal = {Abdominal Radiology},
  year = {2023},
  volume = {49},
  number = {1},
  pages = {103--116},
  doi = {10.1007/s00261-023-04042-5}
}
Kostenlos starten →